1 Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK :536.2: UDC :536.2: J. Strokovni Remec - ~lanek A. Arhar: (1.04) Mo`nosti za zmanj{anje - The Possibilities of Reducing Speciality paper (1.04) Mo`nosti za zni`anje temperature toplotnega vira z absorpcijskimi hladilnimi napravami The Possibilities of Reducing the Temperature of the Heat Source for Absorption Chillers Janko Remec - Andrej Arhar Poveèanje pomembnosti s simultano proizvodnjo elektrike sprožijo toplota in mraz stroge zahteve po uporabi absorpcijskih hladilnikov. Naprave bi morale biti manjše, imeti manjšo hladilno zmogljivost in uporabljati nizko temperaturno ogrevano vodo pri 90 C ali nižjo. Zaradi tega so potrebne spremembe v konstrukciji generatorja. Padajoèi sloj omogoèa generatorjem uporabo vroèe vode pri nižjih temperaturah. Omenjen tip generatorjev se izogiba visokim hidrostatiènim tlakom, potrebuje nižje pregretje in zmanjšuje mešanje raztopin. Zaradi tega lahko uporabimo za približno 7 C nižjo temperaturo vroèe vode za dosego enakih hladilnih zmogljivosti Strojniški vestnik. Vse pravice pridržane. (Kljuène besede: generatorji, sloj padajoèi, litijev bromid, prenos toplote) The increasing importance of the simultaneous production of electricity, heat and cold results in increasingly rigorous demands on absorption chillers. These devices should be smaller, having a low cooling capacity and they have to be able to use low-temperature heating water at 90 C or below. As a result, changes in generator construction are needed. Falling-film generators allow the use of hot water with lower temperatures. This type of generator avoids the need for high hydrostatic pressure, requires lower superheating and diminishes solution mixing. Consequently, we can use hot water at a temperature 7 C lower and reach the same cooling capacity Journal of Mechanical Engineering. All rights reserved. (Keywords: generators, falling-film, lithium bromide, heat transfer) 0 UVOD Sistemi za soproizvodnjo toplotne in elektriène energije (STEE - CHP) imajo visoke energijske izkoristke, v primeru kadar uporabimo vso pridobljeno toplotno in elektrièno energijo. Temperaturni nivoji toplote so odvisni od izbrane naprave. Plinske turbine omogoèajo proizvodnjo pare, medtem ko plinski dizelski motorji proizvajajo samo vroèo vodo na temperaturnem nivoju pod 100 C, obièajno 90 C. V primeru manjših izvedb (pod 1 MW elektriène moèi), so v uporabi dizelski motorji. Njihova prednost je v prilagajanju obremenitvam in dobrem izkoristku v širokem obmoèju obremenitev. Para iz plinske turbine se lahko uporabi v industrijske namene. Toploto dizelskih motorjev odvajamo z vodo, ki se lahko uporabi samo za ogrevanje. V obeh primerih se pojavi presežek toplote v poletnem obdobju. Toploto moramo odvesti v okolico, za kar potrebujemo dodatno energijo. Hkrati so v poletnem èasu prièakovane veèje potrebe po hladu. Presežek toplote iz STEE lahko uporabimo v 0 INTRODUCTION Systems for combined heat and power (CHP) have a high energy efficiency when they use all the heat and power produced. The temperature levels of the heat depend on the selected device. Gas turbines are able to produce steam, but gas diesel engines only produce hot water at temperatures below 100 C, usually about 90 C. When the facilities are small (under 1 MW of electrical power), diesel engines are the preferred choice. Their advantages are operating flexibility and good efficiency over a wide range of loads. The steam from gas turbines can be used in industrial applications. Waste heat from diesel engines is rejected with the water which can only be used for heating. In both cases there is a surplus of heat in summer time which has to be put into the environment with the use of additional energy. At the some time in summer a greater demand for cooling is expected. Excess heat from CHP systems should stran 564

2 absorpcijskih hladilnikih za proizvodnjo hladu. Za pogon absorpcijskih hladilnikov najpogosteje ostane le nizkotemperaturna toplota. Na podroèju absorpcijskih hladilnih naprav z majhno hladilno moèjo, ki jih poganja nizkotemperaturna vroèa voda, je trg sorazmerno majhen. Eden glavnih vzrokov je visoka cena, ki je povezana z majhnim povpraševanjem po absorpcijskih hladilnih naprav. Trg je bolje razvit v Aziji in še predvsem na Japonskem. Uvoz z daljnjega vzhoda je onemogoèen zaradi stroškov prevoza in neusklajenosti s predpisi v ES, kar je pomembno predvsem za hladilne naprave z majhno hladilno moèjo. Na trgu obstajata dve vrsti absorpcijskih hladilnih naprav, ena temelji na krožnem procesu z enojnim uèinkom in druga z dvojnim uèinkom, obe pa kot delovni par uporabljata vodno raztopino litijevega bromida. Pri obeh vrstah lahko za pogon uporabljamo plin ali paro, medtem ko nizkotemperaturna vroèa voda zadošèa le za pogon naprav z enojnim uèinkom. Hladilne naprave, ki delujejo z delovnim parom amoniak/voda, so manj primerne, zaradi manjših vrednosti hladilnega števila (HŠ - COP) v enakih razmerah. 1 VPLIV NA HŠ IN HLADILNO ZMOGLJIVOST Krožni procesi z enojnim uèinkom so najprimernejši za absorpcijske hladilne naprave, ki so gnane z nizkotemperaturno vroèo vodo. Spremembe vstopne in izstopne temperature povzroèijo spremembo delovne toèke absorpcijske hladilne naprave. Spreminjanje delovne toèke lahko ublažimo s spremembo nivojev in koncentracij v napravi. Èe so spremembe prevelike, se spremeni mehanizem prenosa toplote in snovi. Teh sprememb ne moremo veè kompenzirati. Toploto za pogon dovajamo v generator absorpcijske hladilne naprave. Nizka temperatura dovedene tople vode zahteva nizek tlak v generatorju. Tlak je odvisen od koncentracije raztopine in temperature v kondenzatorju. Znižanje koncentracije zniža uèinkovitost absorberja zato ne moremo doseèi nizke temperature na izstopu. Nižjo temperaturo v kondenzatorju pa dosežemo z nižjo temperaturo hladilne vode. Delovanje absorpcijskih hladilnih naprav ni odvisno samo od vstopne temperature vroèe vode, ampak tudi od temperature na izstopu. Izbrali smo primer s temperaturo hlajene vode na vstopu 12 C in 7 C na izstopu ter vstopno temperaturo vroèe vode 90 C. Slika 1 prikazuje vpliv izstopne temperature vroèe vode in hladilne vode na hladilno moè naprave pri nespremenjenem volumskem pretoku. Komercialne absorpcijske hladilne naprave so bile konstruirane za pogon s paro in kasneje prilagojene za vroèo vodo pod 100 C (veè cevi v generatorju in kondenzatorju). be used in absorption chillers to produce cold. Only low-level hot water is usually available for these applications. There is a relatively small market for absorption chillers with low cooling capacities driven by low-temperature hot water. One of the main reasons for the small market is the high price which is the result of the low sales of these chillers. The market is, however, more developed in Japan and SE Asia. Importation of these chillers from the far East is obstructed by transport costs and harmonization with EU regulations. This is especially important for lowcapacity chillers. Two types of absorption chiller exist on the market, one based on single and another on doubleeffect cycles, both using aqueous lithium-bromide solution as the working pair. Both types could be driven by steam or gas, but for low-temperature hotwater applications only the single-effect chillers are apropriate. Chillers with amonia-water as the working pair are less convenient because of the lower COP for the same conditions. 1 INFLUENCES ON COP AND COOLING CAPACITY Single-effect chillers are the most suitable for absorption chillers driven by low- temperature hot water. Changes of any inlet or outlet temperature cause a different working point of the absorption chiller. Construction can compensate for these changes with different liquid levels and concentrations in the elements of the chiller. If the changes are too large, heat- and mass-transfer mechanisms can be changed too. These changes cannot be compensated any more. Driving heat is put into the generator of the absorption chiller. A low hot-water input temperature requires a low pressure in the generator. Pressure depends on the concentration of the solution and the temperature in the condenser. The decrease in concentration reduces the absorber efficiency and the outlet chilled-water temperature cannot be reached. A lower temperature in the condenser is reached with a lower temperature of the cooling water. But both possibilities are limited. The operation of absorption chillers depends not only on the inlet temperature of the hot water but also on its outlet temperature. We have selected an example with the temperature of chilled water at 12 C for the inlet and 7 C for the outlet and inlet hot-water temperature of 90 C. Figure 1 shows the influence of different outlet temperatures of hot water and inlet cooling-water temperature with a constant volume flow on the cooling capacity. It is a commercial absorption chiller designed to be driven by steam and adapted for hot water under 100 C (more tubes in the generator and condenser). stran 565

3 Znižanje temperature vroèe vode do 80 C ne povzroèi izrazitega zmanjšanja vrednosti HŠ, kar pa ne velja za hladilno moè. Moè je odvisna tudi od hladilne vode (sl. 1). V izbranem obmoèju prièakovanih parametrov je zmanjšanje hladilne moèi premosorazmerno z izstopno temperaturo vroèe vode in temperaturo hladilne vode. Znižanje izstopne temperature za 5 C ima za posledico zmanjšanje hladilne moèi za 8 %. Izstopne temperature pod 70 C so manj primerne zaradi velikih notranjih izgub v generatorju in premajhnem pregretju. To povzroèa nepravilno delovanje hladilne naprave [1]. By reducing the temperature of hot water to about 80 C the COP does not decrease drastically, however the cooling capacity is significantly decreased. The capacity depends on the cooling water too (Figure 1). In the selected range of anticipated parameters a decrease of the cooling capacity is linearly proportional to the hot-water outlet temperature and the cooling-water temperature. A reduction of the outlet temperature by 5 C results in a decrease in the cooling capacity by 8%. Outlet temperatures below 70 C are unfavorable because of high internal losses in the generator and too low superheating. This causes incorrect chiller operation [1]. hladilna moè/normalna moè cooling capacity / nominal capacity 1,0 0,8 0,6 0,4 0,2 0,0 vroèa voda - vstop: 90 C hot water inlet: 90 C hladilna voda: konst. prostorninski pretok cooling water: constant volume flow hlajena voda: 7/12 C chilled water: 7/12 C izstopna temp. vroèe vode hot-water outlet temperature 80 C 75 C 70 C C vstopna temperatura hladilne vode cooling water inlet temperature Sl. 1. Vpliv zmanjšanja temperature hladilne vode na hladilno moè [1] Fig. 1. Influence of cooling water temperature decrease on cooling capacity [1] Na trgu dostopne absorpcijske hladilne naprave so bile konstruirane tako, da jih poganja para ali vroèa voda nad 100 C, loèitev hladiva in absorpcijskega sredstva je z vrenjem vodne raztopine litijevega bromida v posodi. Omenjeni naèin vrenja potrebuje visoko pregretje zlasti, kadar uporabljamo vodne raztopine soli. Za dosego toplotnega toka 50 kw/m 2 je potrebno pregretje za 12 C [2]. Pri tem toplotnem toku je v generatorju konvektivno mehurèkasto vrenje. Manjši toplotni tok moèno poveèa površino generatorja in ceno hladilne naprave. Za dosego 50 kw/m 2 v generatorju z gladkimi cevmi (baker-nikel), je potrebna 18 C temperaturna razlika med grelno vodo in raztopino. 2 TEHNIÈNE MOŽNOSTI Nizkotemperaturno ogrevno vodo lahko uporabimo brez sprememb temperature hlajene in Existing commercial absorption chillers were designed to be driven by steam or hot water over 100 C and the separation is carried out by pool boiling of aqueous lithium-bromide solution. This type of boiling needs high superheating, especially when using aqueous salt solutions. To reach a heat flux of 50 kw/m 2 more than 12 C of superheating is needed [2]. At this heat flux, free convectional pool boiling occurs. A lower heat flux would strongly increase the surface of the generator and the price of the chiller. To reach 50 kw/m 2 in a generator with smooth copper-nickel tubes a temperature difference between the hot water and the solution of about 18 C is needed. 2 TECHNICAL POSSIBILITIES We can use low-temperature heating water, without changing the cooling and chilled water stran 566

4 hladilne vode, èe v generatorju: poveèamo površino cevi (i), poveèamo koeficient toplotne prestopnosti (ii) in zmanjšamo hidrostatièni tlak (iii). Spremembe delovnega para ne bomo obravnavali. Prva možnost (i) je najpogosteje uporabljena rešitev. Cilj lahko dosežemo z veèjim številom cevi ali/in z uporabo orebrenih, ožlebljenih ali posebno obdelanih cevi. Èe uporabimo veè cevi, se moèno poveèata velikost hladilne naprave in cena. Prav tako se poveèa kolièina raztopine v napravi in hidrostatièni tlak. Z uporabo cevi z veèjo površino se poveèa samo cena. Koeficient toplotne prestopnosti (ii) je mogoèe poveèati na strani vode in/ali na strani raztopine. Uporaba nizko temperaturne vroèe vode omogoèa nizek tlak v ceveh. Zaradi tega lahko uporabimo bakrene cevi, ki imajo trikrat boljšo toplotno prevodnost, kot obièajno uporabljene Cu-Ni cevi. Z zmanjšanjem debeline stene cevi in spremembo materiala ne vplivamo bistveno (do 3 %) na koeficient toplotne prestopnosti. Pri nizko temperaturnem viru toplote lahko uporaba cevi z poveèano ali izboljšano površino poviša koeficent toplotne prestopnosti na strani raztopine. Koeficient toplotne prestopnosti je moèno odvisen od pregretja. Kadar v generatorju uporabljamo vrenje v sloju, je koeficient toplotne prestopnosti odvisen tudi od gostote masnega toka. Poveèanje gostote masnega toka do 0,15 kg/s. m ima za posledico poveèanja koeficenta toplotne prestopnosti. Z uporabo orebrenih in ožlebljenih cevi je koeficient prenosa toplote skoraj dvakrat veèji [3]. Oba naèina poveèane površine omogoèata boljšo razlitje kapljevine in s tem zmanjšanje suhih površin, ki zmanjšajo povpreèni koeficient toplotne prestopnosti. Celotni koeficient toplotne prestopnosti je odvisen tudi od lete na vodni strani. Omejitve hitrosti na strani vroèe vode so povezane z dopustnim tlaènim padcem. Pri nizkih hitrostih vroèe vode je primerna uporaba cevi s poveèano površino na notranji strani. Slika 2 prikazuje vpliv na koeficient toplotne prestopnosti. Izbrali smo hitrost vroèe vode med 0,5 in 2 m/s v cevi z notranjim premerom 18,5 mm. Majhen premer in relativno velike hitrosti omogoèajo dober koeficient toplotne prestopnosti med vroèo vodo in cevjo. Možna je tudi uporaba veèjih hitrosti, kar daje celo boljše rezultate, pri èemer pa se moèno poveèa tlaèni padec. Na strani raztopine je koeficient toplotne prestopnosti manjši.koeficient toplotne prestopnosti je pri vrenju vodne raztopine LiBr slabši kot pri vrenju èiste vode. Pri vrenju v posodi dosežemo vrednost 5000 W/m 2 K pri pregretju 20 C. Vrenje raztopine v padajoèem sloju na gladke vodoravne cevi da slabše eksperimentalne rezultate [3]. To je v nasprotju z vodo, pri kateri opazimo poveèanje koeficineta toplotne prestopnosti pri nizkih toplotnih tokovih tako na gladkih kot na poveèanih površinah cevi [6]. Vrednost koeficienta toplotne prestopnosti 2500 W/m 2 K dosežemo pri vrenju v posodi pri temperature, with the following changes to the generator: increasing the tube surface (i), increasing the heat-transfer coefficient (ii) and decreasing the hydrostatic pressure (iii). Changing the working pair will not be discussed. The first possibility (i) is the most common solution. We can reach this goal with more tubes or/and using finned, grooved or specially treated tubes. If we use more tubes the chiller size and price will increase significantly. It will also cause an increase of the depth of the solution in a vessel and hydrostatic pressure. In case of non smooth tubes, only the price will be higher. The heat-transfer coefficient (ii) could be increased on thewater side and/or the solution side. Using a low hot-water temperature enables a lower pressure in the tubes. As a consequence we can use Cu tubes with three times better conductivity rather than Cu-Ni tubes which are used in normal situations. The tubewall thickness decreases and the material changes do not influence significantly (up to 3%) the overall heattransfer coefficient. With a low-temperature heat source the use of extended or enhanced surfaces can increase the boiling heat-transfer coefficient of the solution. The heat-transfer coefficient depends strongly on superheating. When using thin-film boiling in a generator, the heat-transfer coefficient also depends on the mass-flow density. The increase of mass-flow density up to 0.15 kg/s. m increases the heat-transfer coefficient. Using finned or grooved tubes the heat transfer coefficient is almost twice a high [3]. Both types of extended surface enable a better spread of liquid and avoid dry surfaces which decrease the average heattransfer coefficient. The overall heat-transfer coefficient also depends on the water side. The limits on the hot-water side are due to the water velocity being restricted by the maximum pressure drop. By using a low hot-water velocity, extended surfaces inside the tube are also a possibility. Figure 2 shows the influence on the overall heat-transfer coefficient. Hot-water velocities between 0.5 and 2 m/s in a tube with a 18.5 mm inner diameter are selected. A small diameter and a relatively high velocity enables good heat-transfer coefficient between the hot water and the tube. The use of a higher velocity is also possible and gives even better results, but the pressure drop increases significantly. On the other hand, heat transfer on the solution side is low. In comparison with water the lithium-bromide boiling heat-transfer coefficient is weak. Using pool boiling, 5000 W/m 2 K can be reached for only 20 C of superheating. Solution boiling in a falling film on smooth horizontal tubes gives poorer experimental results [3]. This is in contrast to water, where a significant increase in the low-heat flux is measured on smooth and structured surfaces [6]. The overall heat-transfer coefficient of 2500 W/m 2 K by pool boiling at a temperature difference of 20 C and a hot-water velocity of 1.5 m/s can be stran 567

5 5000 koeficient prenosa toplote overall heat transfer coefficient W/m 2 K v = 0,5 m/s v = 1 m/s v = 1,5 m/s v = 2 m/s W/m 2 K koeficient prenosa toplote na strani raztopine solution heat transfer coefficient Sl. 2. Vpliv koeficienta prenosa toplote na strani raztopine na celotni prenos toplote pri razliènih hitrostih v ceveh Fig. 2. Influence of the solution heat-transfer coefficient on the solution side on the overall heat transfer with a different velocity in the tubes temperaturni razliki 20 C in hitrosti vroèe vode 1,5 m/s. Podvojitev hitrosti vroèe vode zmanjša potrebno temperaturno razliko za 2,5 C ali zmanjša površino cevi za 20%. Tlak (iii) v generatorju je odvisen od koncentracije raztopine in temperature kondenzacije. Vrenje je lahko v posodi ali v sloju. Cevi pri vrenju v posodi so potopljene v raztopini. Pri generatorjih s reached. Doubling the hot-water velocity decreases the required temperature difference by 2.5 C or decreases the tubes surface area by 20%. Pressure (iii) in the generator depends on the solution concentration and the condensation temperature. We can use pool boiling or thin-film boiling in the generator. Tubes for pool boiling are immersed in the solution and boiling occurs on the tubes. With 12 C 10 povišanje temperature temperature increase h=2 mm; p=40 mbar h=150 mm; p=40 mbar h=2 mm; p=60 mbar h=150 mm; p=60 mbar h=2 mm; p=100 mbar h=150 mm; p=100 mbar masni delež LiBr % mass share LiBr Sl. 3. Uèinek hidrostatiènega tlaka na povišanje temperature Fig. 3. Effect of hydrostatic pressure on temperature increase stran 568

6 pršenjem se na ceveh oblikuje sloj raztopine. Nad snopom cevi je cev, ki razprši raztopino. Uporaba vrenja v sloju zahteva vodoravno postavitev naprave in s tem tudi cevi. Absolutni tlak v generatorju je nizek (~ 70 mbar), zato ima hidrostatièni tlak moèan vpliv. V tankem sloju je poveèanje temperature vrenja zaradi hidrostatiènega tlaka zanemarljiv. Pri vrenju v posodi pa je 150 mm pod nivojem raztopine je tlak približno 25 mbar višji in zaradi tega se poviša temperatura vrenja. Povišanje temperature vrenja v tankem sloju (2 mm) na cevi in cev, ki je 150 mm pod nivojem raztopine, je prikazana na sliki 3. Hidrostatièni tlak ima pri zelo nizkem tlaku v generatorju (40 mbar) in temperaturi v kondenzatorju (29 C) velik vpliv. Uporaba hladilne vode s temperaturo 31 C omogoèa, da doseže temperaturo v kondezatorju okoli 36 C in absolutni tlak 60 mbar. S prehodom iz vrenja v posodi na vrenje v sloju lahko znižamo temperaturo vroèe vode za 6,5 do 7,7 C. Potrebna temperatura vroèe vode se zniža zaradi znižanja hidrostatiènega tlaka. Absolutni tlak 100 mbar je neprimeren za generatorje z nizko temperaturo vroèe vode, saj je ravnotežna temperatura približno 90 C (pri 58 mas. %) brez upoštevanja temperaturne razlike za prenos toplote in vrenja. Pri generatorjih gretih z nizko temperaturno vroèo vodo je pri enakih pogojih vrenje v sloju kapljevine uèinkovitejše od vrenja v posodi. Padajoèi sloj kapljevine v generatorju onemogoèa mešanje raztopine. Zaradi tega imamo doloèeno porazdelitev temperature in koncentracij. Ravnotežna temperatura se moèno poviša pri ceveh v spodnjem delu generatorja. Zaradi omenjenega razloga je priporoèljivo veèje število prehodov vroèe vode skozi snop cevi. Vroèa voda vstopa na spodnjem delu snopa cevi in raztopini z že zvišano temperaturo omogoèa vrenje. V zgornjem delu generatorja je ogrevana voda že nekoliko ohlajena, pri èemer pa ima tudi raztopina nižjo koncentracijo. To omogoèa najveèjo temperaturno razliko med vstopom in iztopom vroèe vode ter zmanšanja eksergijskih izgub. Na ceveh nastala para teè skozi snop cevi v kondenzator. Naloga generatorja je tudi onemogoèiti vstop raztopine v kondenzator v primeru nepravilnega delovanja. Zato je kondenzator namešèen nad generatorjem. Hitrost pare je velika, ker je specifièni volumen velik. Omejitve so pri tlaènem padcu in odnašanju sloja ali kapljic raztopine. Nespremenljivo hitrost in tlaèni padec lahko dosežemo s poveèanjem razmakov med cevmi. Slika 4 prikazuje spremembo temperature in koncentracije na ceveh. Za zmanjšanje prostornine generatorja izberemo izmenièno razvrstitev cevi. Prenosniki toplote s fazno spremembo imajo spremenljiv masni in volumski pretok kapljevine in pare. Zaradi tega se pogosto falling-film generators the layer of the solution is produced by spraying it on the tubes. They require an additional tube, or tubes, for solution distribution above the tube bundle. Additional attention should be paid to setting up the device horizontally, because not only the absorber and evaporator but also the generator is of the falling-film type. Since the absolute pressure in the generator is very low (~70 mbar) the hydrostatic pressure has a strong influence. There is a negligible boiling temperature increase in the thin film because of the hydrostatic pressure. But 150 mm under the solution level the pressure is about 25 mbar higher and consequently the boiling temperature increases. The boiling temperature increases in the case of a thin film (2 mm) on the tube, and the tube which is 150 mm under the solution level can be seen in Figure 3. At a very low pressure (40 mbar) and temperature in the condenser (29 C) the hydrostatic pressure has the greatest influence. The use of cooling water at 31 C causes an internal temperature in the condenser of about 36 C and an absolute pressure of 60 mbar. The decrease in the required hot-water temperature by changing from boiling on immersed tubes to boiling in a falling film is between 6.5 and 7.7 C. This is a realistic hot-water temperature decrease with a reduced hydrostatic pressure. An absolute pressure of 100 mbar is not appropriate for low-temperature hotwater applications because the equilibrium temperature is about 90 C (at 58 wt.%) without any consideration of the temperature difference for heat transfer and boiling. For a low-temperature hot-water generator, thin-film boiling is much more efficient than pool boiling. Falling-film generators also prevent mixing of the containing solution. Therefore, we have a clear concentration and temperature distribution. The equilibrium temperature for tubes with a lower position increases strongly. For this reason, more passes of the hot water through the tube bundle is recommended. The hottest water should inlet at the lower part of the tube bundle and meet with the hottest solution. On the top part, cooled hot water hits the solution with the lowest concentration. This enables the biggest temperature difference between hot-water inlet and outlet and decreases the exergy losses. Vapor generated on the tubes goes through the bundle in the condenser. This is usually above the generator to prevent entry of the solution to the condenser in the case of faulty operation. Vapor velocities should be high because the specific volume is also high. The limitations are pressure drop and the solution-film or droplets carry off. A constant velocity and pressure drop can be maintained with an increased distance between the tubes. Figure 4 presents thetemperature and concentration changes on the tubes. To reduce the volume of the generator an alternating tube arrangement is usually selected. Heat exchangers with a phase change have changeable mass and volume- stran 569

7 cevna vrsta tube row izenaèena temperatura v C equilibrium temperature [ C] koncentracija v % concentration [wt.%] tlaèni padec v n-ti vrsti v Pa perssure drop to n-th row [Pa] smer pare vapor direction C, %, Pa Sl. 4. Ravnotežna temperatura na površini raztopine, povpreèna temperatura in celotni tlaèni padec do n-te vrste cevi (levo) in cevni porazdeljenosti (desno) Fig. 4. Equilibrium surface temperature, average concentration and total pressure drop to the n-th tube row (left) and tube distribution (right) uporablja spremenljiva razdalja med cevmi. Pri izraèunu smo zanemarili mešanje raztopine in konstanten toplotni tok na vseh ceveh (70 kw/m 2 ). Navpiène razdalje med cevmi so izbrane z uporabo nespremenljive hitrosti pare (20m/s), med stolpci je vseskozi enaka razdalja, ki znaša 35 mm. Tlaèni padec je majhen, njegovo linearnost pa dosežemo z nespremenljivo hitrostjo. Poveèanjem hitrosti pare na 100 m/s povzroèi tlaèni padec 140 Pa [4]. Koncentracijsko razlika 5% je dosežemo pri gostoti masnega toka 0,1 kg/(s. m). flow of liquid and vapor so varying spaces between tubes are often used. No solution mixing and constant heat flux on all tubes (70 kw/m 2 ) have been assumed. Vertical distances between tubes are selected on the basis of constant vapor velocity (20 m/s) and horizontal distances are fixed at 35 mm. No significant pressure drop can be seen and linearity is reached because the velocity is constant. The increase in velocity to 100 m/s causes a pressure drop to 140 Pa [4]. A concentration difference of 5% is reached with a mass flux density of 0.1 kg/(s. m). 0 navpièna razdalja med osmi i i+1 vertical distance between axes i i+1 mm cevna vrsta tube row v= 20m/s, razdalja/distance v= 40m/s, razdalja/distance v= 80m/s, razdalja/distance v= 20m/s, tlaèni padec/ pressure drop v= 40m/s, tlaèni padec/ pressure drop v= 80m/s, tlaèni padec/ pressure drop Pa 60 tlaèni padec pressure drop Sl. 5. Tlaèni padec in navpièna razdalja med cevnimi vrstami z razliènimi najveèjimi hitrostmi Fig. 5. Pressure drop and vertical distances between tube rows with different maximum velocities stran 570

8 Najmanjša razdalja med cevmi je 6,5 mm [5]. To omogoèa izdelavo z uvaljanjem cevi in mehansko èišèenje. Tlaèni padec v cevnem snopu je majhen. Slika 5 prikazuje navpièno razdaljo med cevnimi vrstami. Ko pri nespremenljivi vodoravni (40 mm) razdalji med osmi cevi omogoèimo poveèanje hitrosti, se bo navpièna razdalja zmanjšala. Pri izbrani najveèji dovoljeni hitrosti (80 m/s) je razdalja nespremenljiva in omejena z najmanjšo razdaljo med cevmi. Gradient tlaène razlike se zmanjša zaradi manjše hitrosti. Izbrana srednja hitrost (40 m/s) zahteva veèjo navpièno razdaljo med cevmi v zgornjem delu prenosnika. Omenjeni uèinek je še znaèilnejši pri nižji hitrosti (20 m/s), pri kateri samo zadnje tri cevi dosežejo najmanjšo razdaljo (omejena z najmanjšo razdaljo med cevmi). Tlaèni padec med cevmi je nespremenljiv, dokler je razdalja doloèena s hitrostjo. V teh razmerah padec tlaka povzroèi povišanje temperature za približno 0,1 C (pri 60 mbar in 55 %). Hitrost in tlaèni padec padata, ko je omejitev razdalja med cevmi. Z veèjo hitrostjo je mogoèe zmanjšati višino cevnega snopa iz 240 mm (20 m/s) na 180 mm (80 m/s). Najmanjša razdalja med cevnimi vrstami v generatorju je doloèena s tehnologijo izdelave generatorja. Velika hitrost pare ne povzroèi izrazitejšega tlaènega padca in povišanja temperature. Zaradi tega je primerno zmanjšati izmere generatorja. 3 SKLEP Veèina absorpcijskih hladilnih naprav uporablja v generatorju vrenje v posodi. Njihova konstrukcija je robustna. Pri vrenju v posodi je potrebna visoka vstopna temperatura grelne vode, ki omogoèa pregretje in tudi mešanje raztopine. Znižanje vstopne in/ali izstopne temperature bistveno ne poslabša HŠ, ampak povzroèi padec hladilne moèi v absorpcijskih hladilnih napravah. Pomemben napredek pri uporabi nizkotemperaturne tople vode so dosegli, s spremembo naèina vrenja v generatorju - prehod iz vrenja v posodi na vrenje v sloju. Zaradi znižanja hidrostatiènega tlaka lahko uporabimo za približno 7 C hladnejšo grelno vodo. Pri nižjem tlaku (nižji temperaturi hladilne vode) je vpliv še mnogo veèji. Uèinek vrenja v sloju je veèji, èe je veè prehodov vroèe vode, vstop vroèe vode pa je na spodnjem delu generatorja. Dodatno poveèanje lahko dosežemo z veèjo hitrostjo vroèe vode, rezultat tega je višji tlaèni padec na strani vroèe vode. S poveèanjem hitrosti vroèe vode iz 1,5 na 3 m/s lahko znižamo njeno temperaturo za 2,5 C. Z uporabo razširjene površine (orebrene ali ožlebljene cevi) se poveèa koeficient toplotne prestopnosti raztopine skoraj za 100 %. Zmanjšanje debeline stene cevi in sprememba materiala nimata izrazitega vpliva (do 3 %) na koeficient toplotne prestopnosti. Generirana vodna para ima majhen vpliv na tlak v generatorju. Povišanje temperature zaradi padca tlaka je najvišje na spodnjih ceveh in pri hitrosti pare 80 m/s znaša samo 0,1 C. The minimum gap between tubes is set to 6.5 mm [5]. This enables tube end attachment with roller expansion and mechanical cleaning. The pressure drop in the tube bundle shell be low. Figure 5 shows the vertical distances between tube rows. When at a constant (40 mm) horizontal distance, the allowed velocity is increased the vertical distance will be decreased. At the highest selected velocity (80 m/s) the distance is constant and limited with a minimum gap. The gradient of pressure difference decreases because of the lower velocities. A medium velocity (40 m/s) requires a higher vertical distance between the tubes in the upper half of the exchanger. This effect is more significant at the lowest velocity (20 m/s) where only the last three tubes reach the minimum distance (limited with a minimum gap). The pressure drop between tubes (one above another) is constant as long as the distance is defined by velocity. Under these conditions pressure drop causes a temperature increase of about 0.1 C (at 60 mbar and 55 wt.%). When the gap is at the limit, the velocity and pressure drop decrease. With a higher velocity the height of the tube bundle can be reduced from 240 mm (20 m/s) to 180 mm (80 m/s). With a small number of tube rows in the generator the distance between them is defined by production technology. High vapor velocities have not caused a significant pressure drop and temperature increase. As a result, it is reasonable to decrease the dimensions of the generator. 3 CONCLUSION Most absorption chillers use pool boiling of the solution in a generator. Their construction is robust. On the other hand, a high temperature of the input heat is required not only for superheating but also for mixing of the solution. Lowering input and/ or output temperatures does not make the COP significantly worse but causes a reduction in the cooling capacity of the absorption chillers. Using low-temperature hot water the greatest improvement is achieved when changing from a poolboiling generator to a falling-film generator. About 7 C cooler driving water can be used and the hydrostatic pressure is reduced. At low pressure (low cooling-water temperature) the influence is even stronger. The effect is greater with more passes of hot water with the inlet at the bottom of the tube rows of the generator. Improvements can be obtained with higher hot-water velocity but the result is a higher pressure drop too. We can reduce the hot-water temperature by 2.5 C if we increase its velocity from 1.5 to 3 m/s. Using extended surfaces (finned or grooved tubes) the solution heattransfer coefficent is increased by almost 100%. The tube-wall thickness decreases and material changes do not significantly influence (up to 3%) the overall heattransfer coefficient. The pressure drop of the generated steam through the tube bundle has a negligible effect. It causes a temperature of increase for only 0.1 C on the lower tubes by using vapor velocities of about 80 m/s. stran 571

9 Generatorji z vrenjem v posodi niso primerni za pogon z nizkotemperaturno toplo vodo. V takšnih primerih uporabljamo vrenje v sloju, kar omogoèa optimalno konstrukcijo in razmeroma nizke proizvodne stroške. We can conclude that generators with pool boiling are not convenient for low hot-water temperatures. Falling-film generators should be used for such applications, because they enable optimum design and production costs. 4 LITERATURA 4 REFERENCES [1] Arhar, A., J. Remec (1999) Daljinsko hlajenje v klimatizaciji. II strokovno posvetovanje SDDE, , Portorož. [2] Kamoshida, J., N. Isshiki (1994) Heat transfer to water/lithium halide salt solutions in nuclear pool boiling. Proceedings ofthe International Absorption Heat Pump Conference, New Orleans. [3] Wang, C., Z. Lu, J. Zhou (1999) Enhancement of heat and mass transfer in lithium bromide falling film generator. Proceedings of the International Sorption Heat Pump Conference, München. [4] Idelchik, I. E. (1996) Handbook of hydraulic resistance, 3 ed., Begell House, Inc., New York. [5] Chenoweth, I. (1983) Heat exchanger design handbook. Hemisphere Publishing Corporation, Washington. [6] Chyum, M. C., A. E. Bergles (1989) Horizontal-tube falling-film evaporation with structured surfaces. Journal of Heat Transfer Transection of the ASME, Vol. I II, Naslova avtorjev: dr. Janko Remec Fakulteta za strojništvo Univerze v Ljubljani Aškerèeva Ljubljana Andrej Arhar Install, d.o.o Ljubljana Authors Addresses: Dr. Janko Remec Faculty of Mechanical Eng University of Ljubljana Aškerèeva Ljubljana, Slovenia Andrej Arhar Install, Ltd Ljubljana Prejeto: Received: Sprejeto: Accepted: stran 572

Gospodarjenje z energijo

Gospodarjenje z energijo 1 Alternativne delovne snovi A Uvod Vir toplote za delovne krožne procese je običajno zgorevanje fosilnih goriv ali jedrska reakcija, pri katerih so na razpolago relativno visoke temperature, s tem pa

Prikaži več

Strojni{ki vestnik 46(2000)10, Journal of Mechanical Engineering 46(2000)10, ISSN ISSN UDK : UDC 6

Strojni{ki vestnik 46(2000)10, Journal of Mechanical Engineering 46(2000)10, ISSN ISSN UDK : UDC 6 Strojni{ki vestnik 46(2)1,66-67 Journal of Mechanical Engineering 46(2)1,66-67 ISSN 39-248 ISSN 39-248 UDK 621.5.48:621.5.11 UDC 621.5.48:621.5.11 A. Izvirni Poredo{ znanstveni - D. @iher: ~lanek Vpliv

Prikaži več

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK : UDC 621.

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK : UDC 621. Strojni{ki vestnik 46(2000)8,517-524 Journal of Mechanical Engineering 46(2000)8,517-524 ISSN 0039-2480 ISSN 0039-2480 UDK 621574013:62092 UDC 621574013:62092 Pregledni V znanstveni Vasi} - J Krope ~lanek

Prikaži več

Strojni{ki vestnik 46(2000)10, Journal of Mechanical Engineering 46(2000)10, ISSN ISSN UDK : UDC 6

Strojni{ki vestnik 46(2000)10, Journal of Mechanical Engineering 46(2000)10, ISSN ISSN UDK : UDC 6 Strojni{ki vestnik 46(2000)10,671-682 Journal of Mechanical Engineering 46(2000)10,671-682 ISSN 0039-2480 ISSN 0039-2480 UDK 621.5.013:621.5.011 UDC 621.5.013:621.5.011 Izvirni znanstveni ~lanek B. (1.01)

Prikaži več

Športno društvo Jesenice, Ledarska 4, 4270 Jesenice, Tel.: (04) , Fax: (04) , Drsalni klub Jesenice in Zv

Športno društvo Jesenice, Ledarska 4, 4270 Jesenice, Tel.: (04) , Fax: (04) ,   Drsalni klub Jesenice in Zv Drsalni klub Jesenice in Zveza drsalnih športov Slovenije RAZPISUJETA TEKMOVANJE V UMETNOSTNEM DRSANJU Biellman Cup 1. Organizator: Drsalni klub Jesenice, Ledarska ulica 4, 4270 JESENICE www.dkjesenice.si

Prikaži več

Toplotne črpalke

Toplotne črpalke VGRADNJA KOMPAKTNEGA KOLEKTORJA ZA OGREVANJE NIZKENERGIJSKE HIŠE S TOPLOTNO ČRPALKO ZEMLJA/VODA Vgradnja kompaktnega zemeljskega kolektorja v obliki košare prihrani 75 % površino zemlje v primerjavi z

Prikaži več

Strojni{ki vestnik 46(2000)7, Journal of Mechanical Engineering 46(2000)7, ISSN ISSN UDK 620.9:628.8: UDC

Strojni{ki vestnik 46(2000)7, Journal of Mechanical Engineering 46(2000)7, ISSN ISSN UDK 620.9:628.8: UDC Strojni{ki vestnik 46(2000)7,454-465 Journal of Mechanical Engineering 46(2000)7,454-465 ISSN 0039-2480 ISSN 0039-2480 UDK 620.9:628.8:621.574.013 UDC 620.9:628.8:621.574.013 P. Pregledni Donjerkovi} znanstveni

Prikaži več

Microsoft Word - ge-v01-osnove

Microsoft Word - ge-v01-osnove .. Hidroelektrarna Gladina akumulacijskega jezera hidroelektrarne je 4 m nad gladino umirjevalnega bazena za elektrarno. Skozi turbino teče 45 kg/s vode. Temperatura okolice in vode je 0 C, zračni tlak

Prikaži več

PowerPoint Presentation

PowerPoint Presentation Laboratorij za termoenergetiko Jedrska elektrarna 1 Zanimivosti, dejstva l. 1954 prvo postrojenje (Obninsk, Rusija): to postrojenje obratovalo še ob prelomu stoletja; ob koncu 2001 so jedrske elektrarne

Prikaži več

Uporaba OVE v stavbah

Uporaba OVE v stavbah Sončna energija in stavbe Ogrevanje in hlajenje stavb s soncem Dr. Sašo Medved, Univerza v Ljubljani, Fakulteta za strojništvo Vrste SOS pasivni sistemi ; integrirani v stavbe aktivni sistemi ; ogrevalni

Prikaži več

Strojniški vestnik (44) št. 3-4, str , 1998 Journal of Mechanical Engineering (44) No. 3-4, pp , 1998 Tiskano v Sloveniji. Vse pravice pri

Strojniški vestnik (44) št. 3-4, str , 1998 Journal of Mechanical Engineering (44) No. 3-4, pp , 1998 Tiskano v Sloveniji. Vse pravice pri Strojniški vestnik (44) št. 3-4, str. 84-96, 1998 Journal of Mechanical Engineering (44) No. 3-4, pp. 84-96, 1998 Tiskano v Sloveniji. Vse pravice pridržane. Printed in Slovenia. All rights reserved. UDK

Prikaži več

Preštudirati je potrebno: Floyd, Principles of Electric Circuits Pri posameznih poglavjih so označene naloge, ki bi jih bilo smiselno rešiti. Bolj pom

Preštudirati je potrebno: Floyd, Principles of Electric Circuits Pri posameznih poglavjih so označene naloge, ki bi jih bilo smiselno rešiti. Bolj pom Preštudirati je potrebno: Floyd, Principles of Electric Circuits Pri posameznih poglavjih so označene naloge, ki bi jih bilo smiselno rešiti. Bolj pomembne, oziroma osnovne naloge so poudarjene v rumenem.

Prikaži več

Društvo za elektronske športe - spid.si Vaneča 69a 9201 Puconci Pravila tekmovanja na EPICENTER LAN 12 Hearthstone Na dogodku izvaja: Blaž Oršoš Datum

Društvo za elektronske športe - spid.si Vaneča 69a 9201 Puconci Pravila tekmovanja na EPICENTER LAN 12 Hearthstone Na dogodku izvaja: Blaž Oršoš Datum Pravila tekmovanja na EPICENTER LAN 12 Hearthstone Na dogodku izvaja: Blaž Oršoš Datum: 5. januar 2016 Društvo za elektronske športe [1/5] spid.si Slovenska pravila 1 OSNOVNE INFORMACIJE 1.1 Format tekmovanja

Prikaži več

Dinamika požara v prostoru 21. predavanje Vsebina gorenje v prostoru in na prostem dinamika gorenja v prostoru faze, splošno kvantitativno T

Dinamika požara v prostoru 21. predavanje Vsebina gorenje v prostoru in na prostem dinamika gorenja v prostoru faze, splošno kvantitativno T Dinamika požara v prostoru 21. predavanje Vsebina gorenje v prostoru in na prostem dinamika gorenja v prostoru faze, splošno kvantitativno T pred požarnim preskokom Q FO za požarni preskok polnorazviti

Prikaži več

Generatorji toplote

Generatorji toplote Termodinamika Ničti zakon termodinamike Če je telo A v toplotnem ravnovesju s telesom B in je telo B v toplotnem ravnovesju s telesom C, je tudi telo A v toplotnem ravnovesju s telesom C. Prvi zakon termodinamike

Prikaži več

PowerPoint Presentation

PowerPoint Presentation Tehnološki izzivi proizvodnja biometana in njegovo injiciranje v plinovodno omrežje prof. dr. Iztok Golobič Predstojnik Katedre za toplotno in procesno tehniko Vodja Laboratorija za toplotno tehniko Fakulteta

Prikaži več

PRESENT SIMPLE TENSE The sun gives us light. The sun does not give us light. Does It give us light? Raba: Za splošno znane resnice. I watch TV sometim

PRESENT SIMPLE TENSE The sun gives us light. The sun does not give us light. Does It give us light? Raba: Za splošno znane resnice. I watch TV sometim PRESENT SIMPLE TENSE The sun gives us light. The sun does not give us light. Does It give us light? Za splošno znane resnice. I watch TV sometimes. I do not watch TV somtimes. Do I watch TV sometimes?

Prikaži več

PowerPointova predstavitev

PowerPointova predstavitev Slovenija znižuje CO 2 : dobre prakse INTEGRACIJA SPREJEMNIKOV SONČNE ENERGIJE V SISTEM DOLB VRANSKO Marko Krajnc Energetika Vransko d.o.o. Vransko, 12.4.2012 Projekt»Slovenija znižuje CO 2 : dobre prakse«izvaja

Prikaži več

UNIVERZA V MARIBORU FAKULTETA ZA ELEKTROTEHNIKO, RAČUNALNIŠTVO IN INFORMATIKO VISOKOŠOLSKI STROKOVNI ŠTUDIJ Elektrotehnika Močnostna elektrotehnika PO

UNIVERZA V MARIBORU FAKULTETA ZA ELEKTROTEHNIKO, RAČUNALNIŠTVO IN INFORMATIKO VISOKOŠOLSKI STROKOVNI ŠTUDIJ Elektrotehnika Močnostna elektrotehnika PO UNIVERZA V MARIBORU FAKULTETA ZA ELEKTROTEHNIKO, RAČUNALNIŠTVO IN INFORMATIKO VISOKOŠOLSKI STROKOVNI ŠTUDIJ Elektrotehnika Močnostna elektrotehnika POROČILO PRAKTIČNEGA IZOBRAŽEVANJA v TERMOSOLAR d.o.o.,

Prikaži več

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK 532.5: :697.4 UDC 532

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK 532.5: :697.4 UDC 532 Strojni{ki vestnik 46(2000)8,525-531 Journal of Mechanical Engineering 46(2000)8,525-531 ISSN 0039-2480 ISSN 0039-2480 UDK 532.5:621.644:697.4 UDC 532.5:621.644:697.4 Pregledni znanstveni A.Krope - ~lanek

Prikaži več

Microsoft Word - D-4-Senegacnik-SLO.doc

Microsoft Word - D-4-Senegacnik-SLO.doc 20. posvetovanje "KOMUNALNA ENERGETIKA / POWER ENGINEERING", Maribor, 2011 1 ORC PROCES ORGANSKI DELOVNI KROŽNI PROCESI TUDI V SLOVENIJI Andrej SENEGAČNIK, Uroš GLAVINA, Mihael SEKAVČNIK POVZETEK Članek

Prikaži več

Strojni{ki vestnik 49(2003)6, Journal of Mechanical Engineering 49(2003)6, ISSN ISSN UDK :665.72: UDC 62

Strojni{ki vestnik 49(2003)6, Journal of Mechanical Engineering 49(2003)6, ISSN ISSN UDK :665.72: UDC 62 Strojni{ki vestnik 49(2003)6,322-345 Journal of Mechanical Engineering 49(2003)6,322-345 ISSN 0039-2480 ISSN 0039-2480 UDK 621.18:665.72:536.24 UDC 621.18:665.72:536.24 Ba{i~ Izvirni S., znanstveni [kerget

Prikaži več

Diapositiva 1

Diapositiva 1 Različni pogledi na proizvodnjo in rabo energije v prometu, stavbah in v industriji Andrej Kitanovski, Univerza v Ljubljani, Fakulteta za strojništvo EPC - Energy Policy Consideration, GZS, Ljubljana 2019

Prikaži več

1

1 1 KAZALO Kazalo 2 Ogled Toplarne Moste 3 Zgodovina 3 Splošno 4 O tovarni 5 Okolje 6 2 Ogled Toplarne Moste V ponedeljek ob 9.20 uri smo se dijaki in profesorji zbrali pred šolo ter se nato odpeljali do

Prikaži več

E__Gradbena fizika_SKRIPTA_TISK.pdf

E__Gradbena fizika_SKRIPTA_TISK.pdf . VIRI Kazalo Vsebina I. Prenos toplote in energijska uèinkovitost stavb 7 II. Navlaževanje gradbenih konstrukcij 121 III. Svetlobno ugodje in osvetlitev stavb IV. Akustika in zavoèna zašèita stavb V.

Prikaži več

Microsoft Word - A-3-Dezelak-SLO.doc

Microsoft Word - A-3-Dezelak-SLO.doc 20. posvetovanje "KOMUNALNA ENERGETIKA / POWER ENGINEERING", Maribor, 2011 1 ANALIZA OBRATOVANJA HIDROELEKTRARNE S ŠKOLJČNIM DIAGRAMOM Klemen DEŽELAK POVZETEK V prispevku je predstavljena možnost izvedbe

Prikaži več

UDK : : Termohidravlične razmere laminarnega toka tekočine y ozkih kanalih Thermo-Hydraulic Conditions of Laminar Fluid Flow in

UDK : : Termohidravlične razmere laminarnega toka tekočine y ozkih kanalih Thermo-Hydraulic Conditions of Laminar Fluid Flow in UDK 621.436:621.43.013:66.045 Termohidravlične razmere laminarnega toka tekočine y ozkih kanalih Thermo-Hydraulic Conditions of Laminar Fluid Flow in Narrow Channels MARJAN DELIČ - LEOPOLD ŠKERGET - IVAN

Prikaži več

Dia 1

Dia 1 SPTE z uplinjanjem lesne biomase Eko vas Kempele, Finska Radoslav Irgl COGENERA, Artim d.o.o. rado.irgl@artim.si Kaj je uplinjanje lesne biomase? Termalna razgradnja biomase Termalna reakcija Delež kisika

Prikaži več

Strojni{ki vestnik 47(2001)3, Journal of Mechanical Engineering 47(2001)3, ISSN ISSN UDK :531.4/ UDC 62

Strojni{ki vestnik 47(2001)3, Journal of Mechanical Engineering 47(2001)3, ISSN ISSN UDK :531.4/ UDC 62 Strojni{ki vestnik 47(2001)3,129-139 Journal of Mechanical Engineering 47(2001)3,129-139 ISSN 0039-2480 ISSN 0039-2480 UDK 620.171:531.4/539.62 UDC 620.171:531.4/539.62 Pregledni M. znanstveni Kalin -

Prikaži več

Strojni{ki vestnik 50(2004)1,3-14 Journal of Mechanical Engineering 50(2004)1,3-14 ISSN ISSN UDK : UDC

Strojni{ki vestnik 50(2004)1,3-14 Journal of Mechanical Engineering 50(2004)1,3-14 ISSN ISSN UDK : UDC Strojni{ki vestnik 50(2004)1,3-14 Journal of Mechanical Engineering 50(2004)1,3-14 ISSN 0039-2480 ISSN 0039-2480 UDK 621.43.031:621.43.06 UDC 621.43.031:621.43.06 Izvirni znanstveni Hribernik ~lanek A.,

Prikaži več

Ceccato_DRB_20-34_IVR_Leaflet_ENG_ indd

Ceccato_DRB_20-34_IVR_Leaflet_ENG_ indd DRB 20-34 Novi rang fiksnih in frekvenčno vodenih kompresorjev Zanesljiv,enostaven,pamete n: Naprednja zanesljivost v stisnjenem zraku TEHNOLOGIJA KI JI LAHKO ZAUPATE DRB 20-34 direktni prenos DRB 20-34

Prikaži več

Elektro predloga za Powerpoint

Elektro predloga za Powerpoint AKTIVNOSTI NA PODROČJU E-MOBILNOSTI Ljubljana, 15. februar 2017 Uršula Krisper Obstoječe stanje Oskrba 120 polnilnic Lastniki in upravljalci Brezplačno polnjenje Identifikacija z RFID ali GSM ali Urbana

Prikaži več

NOVA GENERACIJA KOMPAKTNIH TOPLOTNIH ČRPALK

NOVA GENERACIJA KOMPAKTNIH TOPLOTNIH ČRPALK NOVA GENERACIJA KOMPAKTNIH TOPLOTNIH ČRPALK LASTNOSTI TOPLOTNE ČRPALKE ZRAK/VODA AEROGOR COMPACT W Kompaktna toplotna črpalka zrak/voda je postavljena na prostem Aeorogor Compact (zunanja enota). Pogosto

Prikaži več

Evidenca_prejetih_vlog

Evidenca_prejetih_vlog Evidenca prejetih vlog za projekte prijavljene na Javni poziv objavljen dne 12. 12. 2018 Agencija za energijo v skladu s prvim odstavkom 373. člena Energetskega zakona (Uradni list RS, št. 17/14 in 81/15)

Prikaži več

RAČUNSKO PREVERJANJE DOSEGANJA MERIL snes VSEBINA 1. Faktorji pretvorbe in energijska performančnost (EP P ) 2. Primer poslovne stavbe s plinskim kotl

RAČUNSKO PREVERJANJE DOSEGANJA MERIL snes VSEBINA 1. Faktorji pretvorbe in energijska performančnost (EP P ) 2. Primer poslovne stavbe s plinskim kotl RAČUNSKO PREVERJANJE DOSEGANJA MERIL snes VSEBINA 1. Faktorji pretvorbe in energijska performančnost (EP P ) 2. Primer poslovne stavbe s plinskim kotlom - z energijo drugih naprav 3. Primer poslovne stavbe

Prikaži več

Strojniški vestnik - Journal of Mechanical Engineering 51(2005)1, 3-12 UDK - UDC : Strojniški vestnik - Journal of Mechanical Engineering

Strojniški vestnik - Journal of Mechanical Engineering 51(2005)1, 3-12 UDK - UDC : Strojniški vestnik - Journal of Mechanical Engineering UDK - UDC 621.565:621.58 Izvirni znanstveni èlanek - Original scientific paper (1.01) Prenos toplote v toku ledene brozge Heat Transfer in an Ice-Slurry Flow Alen Šarlah - Alojz Poredoš - Andrej Kitanovski

Prikaži več

Gorivna celica

Gorivna celica Laboratorij za termoenergetiko Delovanje gorivnih celic Najbolj uveljavljeni tipi gorivnih celic Obstaja veliko različnih vrst gorivnih celic, najpogosteje se jih razvršča glede na vrsto elektrolita Obratovalna

Prikaži več

Einsatzgrenzendiagramm

Einsatzgrenzendiagramm Tehnični podatki LA 6ASR Informacije o napravi LA 6ASR Izvedba - Izvor toplote Zunanji zrak - Različica - Reguliranje - Mesto postavitve Zunanje - Stopnje moči Meje uporabe - Min. temperatura vode / Maks.

Prikaži več

Strojni{ki vestnik 50(2004)7/8, Journal of Mechanical Engineering 50(2004)7/8, ISSN ISSN UDK :534-8 UDC 681.1

Strojni{ki vestnik 50(2004)7/8, Journal of Mechanical Engineering 50(2004)7/8, ISSN ISSN UDK :534-8 UDC 681.1 Strojni{ki vestnik 50(2004)7/8,376-385 Journal of Mechanical Engineering 50(2004)7/8,376-385 ISSN 0039-2480 ISSN 0039-2480 UDK 681.125:534-8 UDC 681.125:534-8 Bolte`ar 004.94 M.: Ugotavljanje ob~utljivosti

Prikaži več

Microsoft Word - M docx

Microsoft Word - M docx Š i f r a k a n d i d a t a : Državni izpitni center *M12224223* Višja raven JESENSKI IZPITNI ROK Izpitna pola 3 Pisno sporočanje A) Pisni sestavek (v eni od stalnih sporočanjskih oblik) (150 180 besed)

Prikaži več

Predstavitev projekta

Predstavitev projekta Delavnica Projekcije cen energije Primerjava mednarodnih projekcij cen energije mag. Andreja Urbančič, IJS Ljubljana, 21. 6. 2018 2 Cene na mednarodnih trgih svetovne cene nafte na mednarodnih trgih zemeljskega

Prikaži več

Microsoft Word - ARRS-MS-BR-07-A-2009.doc

Microsoft Word - ARRS-MS-BR-07-A-2009.doc RAZPIS: Javni razpis za sofinanciranje znanstvenoraziskovalnega sodelovanja med Republiko Slovenijo in Federativno Republiko Brazilijo v letih 2010 2012 (Uradni list RS št. 53/2009) Splošna opomba: Vnosna

Prikaži več

UNIVERZA V MARIBORU FAKULTETA ZA STROJNIŠTVO Janez JELEN OPTIMIRANJE TOPLOTNE ČRPALKE ZRAK- VODA Z ZUNANJIM TOPLOTNIM PRENOSNIKOM Diplomsko delo Visok

UNIVERZA V MARIBORU FAKULTETA ZA STROJNIŠTVO Janez JELEN OPTIMIRANJE TOPLOTNE ČRPALKE ZRAK- VODA Z ZUNANJIM TOPLOTNIM PRENOSNIKOM Diplomsko delo Visok UNIVERZA V MARIBORU FAKULTETA ZA STROJNIŠTVO Janez JELEN OPTIMIRANJE TOPLOTNE ČRPALKE ZRAK- VODA Z ZUNANJIM TOPLOTNIM PRENOSNIKOM Visokošolskega strokovnega študijskega programa Strojništvo Maribor, September

Prikaži več

ZAHTEVA ZA VZDRŽEVANJE LEI (sklad) REQUEST FOR A MAINTENANCE OF LEI (fund) 1. PODATKI O SKLADU / FUND DATA: LEI: Ime / Legal Name: Druga imena sklada

ZAHTEVA ZA VZDRŽEVANJE LEI (sklad) REQUEST FOR A MAINTENANCE OF LEI (fund) 1. PODATKI O SKLADU / FUND DATA: LEI: Ime / Legal Name: Druga imena sklada ZAHTEVA ZA VZDRŽEVANJE LEI (sklad) REQUEST FOR A MAINTENANCE OF LEI (fund) 1. PODATKI O SKLADU / FUND DATA: LEI: Ime / Legal Name: Druga imena sklada / Other Fund Names: Matična številka / Business Register

Prikaži več

Ceccato_DRA_IVR10-20hp_ENG_Final.indd

Ceccato_DRA_IVR10-20hp_ENG_Final.indd DRA IVR 10-20 hp Prilagodljivi, učinkoviti, pametni: Napredna zanesljivost v stisnjenem zraku AVAILABILIT PARTNERSHIP SERVICEABILIT TEHNOLOGIJA, KI JI LAHKO ZAUPATE RELIABILIT SIMPLICIT AVAILABILIT PARTNERSHIP

Prikaži več

Microsoft PowerPoint - Prek-kakovost-zraka [Samo za branje]

Microsoft PowerPoint - Prek-kakovost-zraka [Samo za branje] Kakovost zraka v bivalnih prostorih doc. dr. Matjaž Prek, univ. dipl. inž. str. 25. januar 2018 ZAKON o graditvi objektov (ZGO-1) 9. člen (gradbeni predpisi) (1) Z gradbenimi predpisi se za posamezne vrste

Prikaži več

PH in NEH - dobra praksa

PH in NEH - dobra praksa Strokovno izpopolnjevanje, UL-FA, 5.4.219 SKORAJ NIČ-ENERGIJSKE JAVNE STAVBE V SLOVENIJI Kako izpolniti zahteve za racionalno in visoko učinkovito javno skoraj nič-energijsko stavbo ter doseči pričakovano

Prikaži več

Toplotne črpalke

Toplotne črpalke FOTOVOLTAIČNI SISTEMI VGRAJENI V TOPLO ZRAČNE SPREJEMNIKE SONČNE ENERGIJE Pri snovanju ogrevalnih sistemov za nizkoenergijske hiše (NEH) v veliko primerih koristimo toplo zračne sprejemnike sončne energije

Prikaži več

KLIMATSKE ZNAČILNOSTI LETA 1993 Aleška Bernot-lvančič* Leto 1993 je bilo glede na podatke 30-letnega klimatološkega niza nadpovprečno toplo, s

KLIMATSKE ZNAČILNOSTI LETA 1993 Aleška Bernot-lvančič* Leto 1993 je bilo glede na podatke 30-letnega klimatološkega niza nadpovprečno toplo, s KLIMATSKE ZNAČILNOSTI LETA 1993 Aleška Bernot-lvančič* Leto 1993 je bilo glede na podatke 30-letnega klimatološkega niza 1961-90 nadpovprečno toplo, sončno in suho. Po vremenu bi ga lahko razdelili na

Prikaži več

ANALIZA HLAJENJA ZRAKA IZ KOMPRESORSKEGA POLNILNIKA PRI AVTOMOBILIH Diplomski seminar na študijskem programu 1. stopnje Fizika Jean Frumen Mentor: doc

ANALIZA HLAJENJA ZRAKA IZ KOMPRESORSKEGA POLNILNIKA PRI AVTOMOBILIH Diplomski seminar na študijskem programu 1. stopnje Fizika Jean Frumen Mentor: doc ANALIZA HLAJENJA ZRAKA IZ KOMPRESORSKEGA POLNILNIKA PRI AVTOMOBILIH Diplomski seminar na študijskem programu 1. stopnje Fizika Jean Frumen Mentor: doc. dr. Mitja Slavinec Somentorica: asist. Eva Klemenčič,

Prikaži več

PH in NEH - dobra praksa

PH in NEH - dobra praksa Strokovno izpopolnjevanje, UL-FA, 5.4.2019 SKORAJ NIČ-ENERGIJSKE JAVNE STAVBE V SLOVENIJI Pravočasno in celovito načrtovanje ter zagotavljanje kakovosti pri gradnji sodobnih opečnih javnih skoraj nič-energijskih

Prikaži več

UDK Kombinirano hlajenje v jedrski elektrarni Krško PREDVIDEVANJA IN IZVEDBA Combined Cooling in the Krško Nuclear Power Plant PREVISIONS

UDK Kombinirano hlajenje v jedrski elektrarni Krško PREDVIDEVANJA IN IZVEDBA Combined Cooling in the Krško Nuclear Power Plant PREVISIONS UDK 621.039.534 Kombinirano hlajenje v jedrski elektrarni Krško PREDVIDEVANJA IN IZVEDBA Combined Cooling in the Krško Nuclear Power Plant PREVISIONS AND IMPLEMENTATION PAVEL KUNC Prvi investicijski elaborat

Prikaži več

PROFILNA TEHNIKA / OPREMA DELOVNIH MEST PROFILE TECHNIC / WORKSTATION ACCESSORIES INFO ELEMENTI / INFO ELEMENTS INFO TABLA A4 / INFO BOARD A4 U8L U8 U

PROFILNA TEHNIKA / OPREMA DELOVNIH MEST PROFILE TECHNIC / WORKSTATION ACCESSORIES INFO ELEMENTI / INFO ELEMENTS INFO TABLA A4 / INFO BOARD A4 U8L U8 U INFO ELEMENTI / INFO ELEMENTS INFO TABLA A4 / INFO BOARD A4 L 8264 Material: jeklo (lakirano RAL 016) Material: steel (painted RAL 016) Teža / Weight = 1895 g Delovne informacije Pritrdilni set / Fastening

Prikaži več

Hartmann-SI.indd

Hartmann-SI.indd Petruzalek d.o.o. Tržaška cesta 43, 2000 Maribor www.petruzalek.si Podjetje GHD Georg Maschinenbau GmbH je vodilno na podroèju rezalnih strojev, strojev za porcioniranje kruhov ter pakirnih strojev. Prav

Prikaži več

BM2

BM2 MOBILNI PROSTORSKI PLINSKI GRELNIK Z DIREKTNIM Za gradbišča, manjše delavnice, plastenjake, steklenjake Direktno zgorevanje, ne potrebuje dimnika. Zelo hitra montaža ker priklopimo samo plinsko jeklenko

Prikaži več

PowerPoint Presentation

PowerPoint Presentation PREDAVANJA Energija in okolje Ogrevanje Topla sanitarna voda Prezračevanje Hlajenje Priprava tople sanitarne vode, ogrevanje, hlajenje in proizvodnja električne energije s sončno energijo s sistemi na

Prikaži več

PowerPointova predstavitev

PowerPointova predstavitev Nizkoogljične tehnologije tudi v industriji Marko KOVAČ Institut Jožef Stefan Center za energetsko učinkovitost Portorož, Slovenija 16. april 2019 Večjega znižanja emisij v industriji ne bo mogoče doseči

Prikaži več

Microsoft Word - PREDMETNIK_1_2_3_2015.doc

Microsoft Word - PREDMETNIK_1_2_3_2015.doc PREDMETNIK 1. letnik Organizirano študijsko delo IŠDŠ VP OŠD Zap. Predmet zimski poletni Št. P V P V PD IŠ PRVI LETNIK 1. Matematična fizika NV 30 45 75 / 135 210 7 2. Osnove tehnologij TV 30 45 75 / 93

Prikaži več

Strojni{ki vestnik 46(2000)7, Journal of Mechanical Engineering 46(2000)7, ISSN ISSN UDK 620.9:64.06(497.5) UDC 620.

Strojni{ki vestnik 46(2000)7, Journal of Mechanical Engineering 46(2000)7, ISSN ISSN UDK 620.9:64.06(497.5) UDC 620. Strojni{ki vestnik 46(2)7,475-482 Journal of Mechanical Engineering 46(2)7,475-482 ISSN 39-248 ISSN 39-248 UDK 62.9:64.6(497.5) UDC 62.9:64.6(497.5) Strokovni B. Frankovi} ~lanek - (1.4) K. Leni}: Dolo~anje

Prikaži več

Slovenska predloga za KE

Slovenska predloga za KE 23. posvetovanje "KOMUNALNA ENERGETIKA / POWER ENGINEERING", Maribor, 2014 1 ANALIZA VPLIVA PRETOKA ENERGIJE PREKO RAZLIČNIH NIZKONAPETOSTNIH VODOV NA NAPETOSTNI PROFIL OMREŽJA Ernest BELIČ, Klemen DEŽELAK,

Prikaži več

SOLARNI SISTEMI ZA OGREVANJE IN PRIPRAVO TOPLE VODE PRI NEH IN PH Pri nizkoenergijskih hišah (NEH) in pasivnih hišah (PH) so sistemi za ogrevanje in p

SOLARNI SISTEMI ZA OGREVANJE IN PRIPRAVO TOPLE VODE PRI NEH IN PH Pri nizkoenergijskih hišah (NEH) in pasivnih hišah (PH) so sistemi za ogrevanje in p SOLARNI SISTEMI ZA OGREVANJE IN PRIPRAVO TOPLE VODE PRI NEH IN PH Pri nizkoenergijskih hišah (NEH) in pasivnih hišah (PH) so sistemi za ogrevanje in pripravo tople sanitarne vode (PTV) nadgrajeni s solarnimi

Prikaži več

UDK Kombinirano hlajenje prototipnih motorjev TAM Combined Air-Oil Cooling of the TAM Prototype Diesel Engine FERDINAND TRENC - JOŽE PRIM

UDK Kombinirano hlajenje prototipnih motorjev TAM Combined Air-Oil Cooling of the TAM Prototype Diesel Engine FERDINAND TRENC - JOŽE PRIM UDK 621.43.065.5 Kombinirano hlajenje prototipnih motorjev TAM Combined Air-Oil Cooling of the TAM Prototype Diesel Engine FERDINAND TRENC - JOŽE PRIMOŽIČ - VALTER VOLF Temperaturni potek v steni valja

Prikaži več

Strojni{ki vestnik 48(2002)10, Journal of Mechanical Engineering 48(2002)10, ISSN ISSN UDK : :536.2 UDC

Strojni{ki vestnik 48(2002)10, Journal of Mechanical Engineering 48(2002)10, ISSN ISSN UDK : :536.2 UDC Strojni{ki vestnik 48(2002)10,541-556 Journal of Mechanical Engineering 48(2002)10,541-556 ISSN 0039-2480 ISSN 0039-2480 UDK 556.33:662.995:536.2 UDC 556.33:662.995:536.2 Strokovni Stritih ~lanek U. -

Prikaži več

Toplotne črpalke

Toplotne črpalke SOLARNI SISTEMI ZA OGREVANJE IN PRIPRAVO TOPLE VODE V NEH IN PH Pri nizkoenergijskih hišah (NEH) in pasivnih hišah (PH) so sistemi za ogrevanje in pripravo tople sanitarne vode (PTV) nadgrajeni s solarnimi

Prikaži več

untitled

untitled ROTEX Sanicube: Kombinacija pretočnega grelnika in hranilnika toplote. ROTEX Sanicube: Higienski grelnik sanitarne vode. Topla sanitarna voda - vedno na voljo, ko jo potrebujete. Del kakovosti življenja

Prikaži več

Powerpoint template pool EN

Powerpoint template pool EN Termična optimizacija pri načrtovanju vezij Delavnica Miha Karlovšek, Ljubljana, Maj 2018 Miha.Karlovsek@hella.com HF-7761EN_C (2014-07) Termična optimizacija Postavitev komponent Dobra optimizacija bakrenih

Prikaži več

ZAŠČITNA IZOLACIJA BREZ VSEBNOSTI HALOGENIH SNOVI ZA ZMANJŠEVANJE KOROZIVNIH UČINKOV IN TOKSIČNOSTI DIMA V PRIMERU POŽARA Powered by TCPDF (

ZAŠČITNA IZOLACIJA BREZ VSEBNOSTI HALOGENIH SNOVI ZA ZMANJŠEVANJE KOROZIVNIH UČINKOV IN TOKSIČNOSTI DIMA V PRIMERU POŽARA Powered by TCPDF ( ZAŠČITNA IZOLACIJA BREZ VSEBNOSTI HALOGENIH SNOVI ZA ZMANJŠEVANJE KOROZIVNIH UČINKOV IN TOKSIČNOSTI DIMA V PRIMERU POŽARA Powered by TCPDF (www.tcpdf.org) Brez vsebnosti halogenih snovi Majhna količina

Prikaži več

UVOD

UVOD Diplomsko delo IZBIRA NAJPRIMERNEJŠEGA HLADIVA ENOSTOPENJSE ALI DVOSTOPENJSE VISOOTEMPERATURNE TOPLOTNE ČRPALE Marec, 2016 Simon Ceglar Simon Ceglar Izbira najprimernejšega hladiva enostopenjske ali dvostopenjske

Prikaži več

PRILOGA II Obrazec II-A Vloga za pridobitev statusa kvalificiranega proizvajalca elektri ne energije iz obnovljivih virov energije 1.0 Splošni podatki

PRILOGA II Obrazec II-A Vloga za pridobitev statusa kvalificiranega proizvajalca elektri ne energije iz obnovljivih virov energije 1.0 Splošni podatki PRILOGA II Obrazec II-A Vloga za pridobitev statusa kvalificiranega proizvajalca elektri ne energije iz obnovljivih virov energije 1.0 Splošni podatki o prosilcu 1.1 Identifikacijska številka v registru

Prikaži več

ecoterm toplotna črpalka PREPROSTA. UČINKOVITA. ZANESLJIVA

ecoterm toplotna črpalka PREPROSTA. UČINKOVITA. ZANESLJIVA ecoterm toplotna črpalka PREPROSTA. UČINKOVITA. ZANESLJIVA 2 ECOTERM Inovativen pristop ter uporaba edinstvene tehnologije v svetu toplotnih črpalk omogočata vrsto uporabnih prednosti, ki jih nudi toplotna

Prikaži več

Strojni{ki vestnik 47(2001)7, Journal of Mechanical Engineering 47(2001)7, ISSN ISSN UDK :006.06: UDC 69

Strojni{ki vestnik 47(2001)7, Journal of Mechanical Engineering 47(2001)7, ISSN ISSN UDK :006.06: UDC 69 Strojni{ki vestnik 47(21)7,325-335 Journal of Mechanical Engineering 47(21)7,325-335 ISSN 39-248 ISSN 39-248 UDK 699.86:6.6:536.21 UDC 699.86:6.6:536.21 Strokovni ~lanek (1.4) B. ^erne - S. Medved: Toplotne

Prikaži več

Javni in zasebni interes na področju storitev za starejše

Javni in zasebni interes na področju storitev za starejše Projekt CoolHeating Ljutomer, 30.5.2017 Rok Sunko rok@skupina-fabrika.com This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement

Prikaži več

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK 536.3:536.2: UDC 536.

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK 536.3:536.2: UDC 536. Strojni{ki vestnik 6(00)8,9-502 Journal of Mechanical Engineering 6(00)8,9-502 ISSN 0039-280 ISSN 0039-280 UDK 536.3:536.2:697.97 UDC 536.3:536.2:697.97 M. Pregledni Prek - znanstveni P. Novak: Analiti~na

Prikaži več

VIESMANN VITOMAX 200-HW Visokotlačni vročevodni kotel za dop. temperature iztoka do 150 C Nazivna toplotna moč 2,3 do 6,0 MW Podatkovni list Naroč. št

VIESMANN VITOMAX 200-HW Visokotlačni vročevodni kotel za dop. temperature iztoka do 150 C Nazivna toplotna moč 2,3 do 6,0 MW Podatkovni list Naroč. št VIESMANN VITOMAX 200-HW Visokotlačni vročevodni kotel za dop. temperature iztoka do 150 C Nazivna toplotna moč 2,3 do 6,0 MW Podatkovni list Naroč. št. in cene na zahtevo VITOMAX 200-HW Tip M72A Visokotlačni

Prikaži več

Sonniger katalog_2017_DE_ indd

Sonniger katalog_2017_DE_ indd GRELNIKI ZRAKA ZRAČNE ZAVESE ŠT. 1 v Evropi Novo v naši ponudbi NOVA zračna zavesa ŠT. 1 v Evropi SONNIGER JE EVROPSKI DOBAVITELJ INOVATIVNIH, EKOLOŠKIH IN OPTIMALNO PRILAGOJENIH GRELNIKOV ZA INDUSTRIJSKE

Prikaži več

Microsoft PowerPoint - Umanotera ppt [Read-Only] [Compatibility Mode]

Microsoft PowerPoint - Umanotera ppt [Read-Only] [Compatibility Mode] Blaženje podnebnih sprememb: strošek ali razvojna priložnost? mag. Mojca Vendramin Okoljska Kuznetsova krivulja Pritiski na okolje na prebiv. Dohodek na prebivalca Neposredni vpliv različnih cen CO 2

Prikaži več

1. Distributivni elementi.indd

1. Distributivni elementi.indd Kompaktna klimatska naprava SMRTY / 119 Tehnični list Namestitev: Stanovanja, Stanovanjske hiše, Vile, Pasivne hiše Prezračevalna naprava za stanovanjske hiše Smarty X z EPP ohišjem je sinonim za najvišjo

Prikaži več

EVROPSKA KOMISIJA Bruselj, XXX [ ](2013) XXX draft DIREKTIVA KOMISIJE.../ /EU z dne XXX o spremembi prilog I, II in III k Direktivi 2000/25/ES Evropsk

EVROPSKA KOMISIJA Bruselj, XXX [ ](2013) XXX draft DIREKTIVA KOMISIJE.../ /EU z dne XXX o spremembi prilog I, II in III k Direktivi 2000/25/ES Evropsk EVROPSKA KOMISIJA Bruselj, XXX [ ](2013) XXX draft DIREKTIVA KOMISIJE.../ /EU z dne XXX o spremembi prilog I, II in III k Direktivi 2000/25/ES Evropskega parlamenta in Sveta o ukrepih, ki jih je treba

Prikaži več

ARS1

ARS1 Nepredznačena in predznačena cela števila Dvojiški zapis Nepredznačeno Predznačeno 0000 0 0 0001 1 1 0010 2 2 0011 3 3 Pri odštevanju je stanje C obratno (posebnost ARM)! - če ne prekoračimo 0 => C=1 -

Prikaži več

Microsoft Word - SevnoIII.doc

Microsoft Word - SevnoIII.doc Naše okolje, april 8 METEOROLOŠKA POSTAJA SEVNO Meteorological station Sevno Mateja Nadbath V Sevnem je klimatološka meteorološka postaja Agencije RS za okolje. Sevno leži na prisojnem pobočju Sevniškega

Prikaži več

Strojni{ki vestnik 46(2000)4, Journal of Mechanical Engineering 46(2000)4, ISSN ISSN UDK : :539.4

Strojni{ki vestnik 46(2000)4, Journal of Mechanical Engineering 46(2000)4, ISSN ISSN UDK : :539.4 Strojni{ki vestnik 46(2000)4,214-229 Journal of Mechanical Engineering 46(2000)4,214-229 ISSN 0039-2480 ISSN 0039-2480 UDK 621.184.2:621.311.25:539.4 UDC 621.184.2:621.311.25:539.4 B. Pregledni Krajnc,

Prikaži več

Priloga I RAZVRSTITEV OPREME POD TLAKOM GLEDE NA STOPNJO NEVARNOSTI Oprema pod tlakom z visoko stopnjo nevarnosti je, glede na vrsto fluida, pogoje ob

Priloga I RAZVRSTITEV OPREME POD TLAKOM GLEDE NA STOPNJO NEVARNOSTI Oprema pod tlakom z visoko stopnjo nevarnosti je, glede na vrsto fluida, pogoje ob Priloga I RAZVRSTITEV OPREME POD TLAKOM GLEDE NA STOPNJO NEVARNOSTI Oprema pod tlakom z visoko stopnjo nevarnosti je, glede na vrsto fluida, pogoje obratovanja in vrsto opreme, razvrš ena v dvanajst skupin

Prikaži več

Microsoft Word - Delovni list.doc

Microsoft Word - Delovni list.doc SVETOVNE RELIGIJE Spoznal boš: krščanstvo - nastanek, širjenje, duhovna in socialna sporočila, vpliv na kulturo islam: nastanek, širjenje, duhovna in socialna sporočila, vpliv na kulturo stik med religijama

Prikaži več

Katera TOPLOTNA ČRPALKA je zame najprimernejša? Prava odločitev! Zrak-voda, zemlja-voda, voda-voda? Kaj je COP - zakaj je pomemben? Koliko znaša letni

Katera TOPLOTNA ČRPALKA je zame najprimernejša? Prava odločitev! Zrak-voda, zemlja-voda, voda-voda? Kaj je COP - zakaj je pomemben? Koliko znaša letni Katera TOPLOTNA ČRPALKA je zame najprimernejša Prava odločitev! Zrak-voda, zemlja-voda, voda-voda Kaj je COP - zakaj je pomemben Koliko znaša letni strošek ogrevanja Nizkotemperaturna ali visokotemperaturna

Prikaži več

ATT

ATT PODATKI O HIŠI V LESCAH NA GORENJSKEM 1. Lokacija: Lesce na Gorenjskem, nadmorska višina 500 m 2. ogrevana površina: 200 m2 3. neogrevana klet, pritličje, nadstropje in del mansarde 4. okna: dvoslojna

Prikaži več

Microsoft Word - SOLARGE_goodpractice_si_innpribostjanu_SI.doc

Microsoft Word - SOLARGE_goodpractice_si_innpribostjanu_SI.doc Stavba Tip stavbe Hotel Število uporabnikov 20,000 Na leto Leto Izgradnje 1991 Celotna ogrevana površina 620 m 2 Poraba tople sanitarne vode 480 m 3 /a, Izračunan Poraba energije za ogrevanje načrtovana

Prikaži več

Zbirni center

Zbirni center OGREVANJE IN HLAJENJE Z ZEMELJSKIMI SONDAMI IN TOPLOTNO ČRPALKO Željko HORVAT GEOTERMALNA ENERGIJA Geotermalna energija je toplota notranjosti Zemlje. V globini je temperatura stalna in z globino narašča.

Prikaži več

Strojni{ki vestnik 49(2003)11, Journal of Mechanical Engineering 49(2003)11, ISSN ISSN UDK : UDC :

Strojni{ki vestnik 49(2003)11, Journal of Mechanical Engineering 49(2003)11, ISSN ISSN UDK : UDC : Strojni{ki vestnik 49(2003)11,549-557 Journal of Mechanical Engineering 49(2003)11,549-557 ISSN 0039-2480 ISSN 0039-2480 UDK 697.97:725.89 UDC 697.97:725.89 Strokovni ~lanek (1.04) Arthur J. H., et al.:

Prikaži več

Diapozitiv 1

Diapozitiv 1 REPUBLIKA SLOVENIJA Ministrstvo za zdravje Štefanova 5, 1000 Ljubljana ZMANJŠANJE PORABE ENERGIJE V SPLOŠNI BOLNIŠNICI NOVO MESTO Dolenjske Toplice, 5.4.2012 Božidar Podobnik, univ.dipl.inž. Vodja projekta

Prikaži več

30 Vpihovalne šobe Vpihovalna šoba VŠ-4 Uporaba Vpihovalne šobe VŠ-4 se uporabljajo za oskrbovanje prostorov s hladnim ali toplim zrakom povsod tam, k

30 Vpihovalne šobe Vpihovalna šoba VŠ-4 Uporaba Vpihovalne šobe VŠ-4 se uporabljajo za oskrbovanje prostorov s hladnim ali toplim zrakom povsod tam, k 30 Vpihovalna šoba VŠ-4 Uporaba VŠ-4 se uporabljajo za oskrbovanje prostorov s hladnim ali toplim zrakom povsod tam, kjer se zahtevajo velike dometne razdalje in nizka stopnja šumnosti. S postavitvijo

Prikaži več