UDK : : Termohidravlične razmere laminarnega toka tekočine y ozkih kanalih Thermo-Hydraulic Conditions of Laminar Fluid Flow in

Podobni dokumenti
UDK Kombinirano hlajenje prototipnih motorjev TAM Combined Air-Oil Cooling of the TAM Prototype Diesel Engine FERDINAND TRENC - JOŽE PRIM

PH in NEH - dobra praksa

Strojniški vestnik - Journal of Mechanical Engineering 51(2005)1, 3-12 UDK - UDC : Strojniški vestnik - Journal of Mechanical Engineering

Dinamika požara v prostoru 21. predavanje Vsebina gorenje v prostoru in na prostem dinamika gorenja v prostoru faze, splošno kvantitativno T

2

HIDRAVLIČNI VENTILI Razvoj dvopotnega tokovnega ventila s tlačnim kompenzatorjem - 2. del Jaka Čadež, Anže Čelik Izvleček: Dvopotni tokovni ventil s t

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK :536.2:

Strojniški vestnik (44) št. 3-4, str , 1998 Journal of Mechanical Engineering (44) No. 3-4, pp , 1998 Tiskano v Sloveniji. Vse pravice pri

Microsoft Word - A-3-Dezelak-SLO.doc

Slovenska predloga za KE

UDK :539.41: Vzporedna analiza toplotnih napetosti v vrtečih sc diskih z enakomerno trdnostjo Simultaneous Analysis of Thermal Stres

UDK 539.3/.4:519.61/.64 Napetosti v vzdolžno prerezanem rotirajočem votlem valju Stresses in Hollow Rotating Cylinder with Longitudinal Split MILAN BA

Strojni{ki vestnik 46(2000)10, Journal of Mechanical Engineering 46(2000)10, ISSN ISSN UDK : UDC 6

VAJE

Microsoft Word - ge-v01-osnove

ANALIZA HLAJENJA ZRAKA IZ KOMPRESORSKEGA POLNILNIKA PRI AVTOMOBILIH Diplomski seminar na študijskem programu 1. stopnje Fizika Jean Frumen Mentor: doc

Gospodarjenje z energijo

Schöck Isokorb tip W Schöck Isokorb tip W W Schöck Isokorb tip W Primeren je za konzolne stenske plošče. Prenaša negativne momente in pozitivne prečne

Gorivna celica

Microsoft Word - ARRS-MS-BR-07-A-2009.doc

Strojni{ki vestnik 48(2002)2,58-72 Journal of Mechanical Engineering 48(2002)2,58-72 ISSN ISSN UDK 532.5:519.61/.64 UDC 532.5:519.

Požarna odpornost konstrukcij

Napotki za izbiro gibljivih verig Stegne 25, 1000 Ljubljana, tel: , fax:

REŠEVANJE DIFERENCIALNIH ENAČB Z MEHANSKIMI RAČUNSKIMI STROJI Pino Koc Seminar za učitelje matematike FMF, Ljubljana, 25. september 2015 Vir: [1] 1

1 Tekmovanje gradbenih tehnikov v izdelavi mostu iz špagetov 1.1 Ekipa Ekipa sestoji iz treh članov, ki jih mentor po predhodni izbiri prijavi na tekm

Microsoft PowerPoint - Prek-kakovost-zraka [Samo za branje]

Einsatzgrenzendiagramm

BM2

Toplotne črpalke

Microsoft PowerPoint - OVT_4_IzolacijskiMat_v1.pptx

Predmet: Course title: UČNI NAČRT PREDMETA / COURSE SYLLABUS Numerično reševanje parcialnih diferencialnih enačb Numerical solving of partial differen

FGG13

Predmet: Course title: UČNI NAČRT PREDMETA/COURSE SYLLABUS Matematična fizika II Mathematical Physics II Študijski programi in stopnja Študijska smer

VIESMANN VITOMAX 200-HW Visokotlačni vročevodni kotel za dop. temperature iztoka do 150 C Nazivna toplotna moč 2,3 do 6,0 MW Podatkovni list Naroč. št

Preštudirati je potrebno: Floyd, Principles of Electric Circuits Pri posameznih poglavjih so označene naloge, ki bi jih bilo smiselno rešiti. Bolj pom

Microsoft PowerPoint - CIGER - SK 3-15 Izkusnje nadzora distribucijskih transformatorjev s pomo... [Read-Only]

Srednja poklicna in strokovna šola Bežigrad - Ljubljana Ptujska ulica 6, 1000 Ljubljana STATISTIKA REGISTRIRANIH VOZIL V REPUBLIKI SLOVENIJI PROJEKTNA

P r e d m e t n i k Seznam skupnih izbirnih predmetov v študijskem programu Izbirni predmeti Zap. št. Predmet Nosilec Kontaktne ure Klinične Pred. Sem

30 Vpihovalne šobe Vpihovalna šoba VŠ-4 Uporaba Vpihovalne šobe VŠ-4 se uporabljajo za oskrbovanje prostorov s hladnim ali toplim zrakom povsod tam, k

TOPLOTNA PREVODNOST IN PREPUSTNOST TKANIN Diplomski seminar na študijskem programu 1. stopnje Fizika Rok Štanc Mentor: doc. dr. Mitja Slavinec Somento

UNIVERZA V MARIBORU

Strojni{ki vestnik 46(2000)8, Journal of Mechanical Engineering 46(2000)8, ISSN ISSN UDK 536.3:536.2: UDC 536.

Ceccato_DRB_20-34_IVR_Leaflet_ENG_ indd

Društvo za elektronske športe - spid.si Vaneča 69a 9201 Puconci Pravila tekmovanja na EPICENTER LAN 12 Hearthstone Na dogodku izvaja: Blaž Oršoš Datum

1 Naloge iz Matematične fizike II /14 1. Enakomerno segreto kocko vržemo v hladnejšo vodo stalne temperature. Kako se spreminja s časom temperat

UČNI NAČRT PREDMETA / COURSE SYLLABUS Predmet: Matematična fizika II Course title: Mathematical Physics II Študijski program in stopnja Study programm

Strojni{ki vestnik 50(2004)7/8, Journal of Mechanical Engineering 50(2004)7/8, ISSN ISSN UDK :534-8 UDC 681.1

Microsoft Word - 9.vaja_metoda porusnih linij.docx

ZAŠČITNA IZOLACIJA BREZ VSEBNOSTI HALOGENIH SNOVI ZA ZMANJŠEVANJE KOROZIVNIH UČINKOV IN TOKSIČNOSTI DIMA V PRIMERU POŽARA Powered by TCPDF (

UNIVERZA V MARIBORU FAKULTETA ZA ELEKTROTEHNIKO, RAČUNALNIŠTVO IN INFORMATIKO VISOKOŠOLSKI STROKOVNI ŠTUDIJ Elektrotehnika Močnostna elektrotehnika PO

PowerPoint Presentation

Microsoft Word - Pravila - AJKTM 2016.docx

UČNI NAČRT PREDMETA / COURSE SYLLABUS Predmet: Numerične metode 1 Course title: Numerical methods 1 Študijski program in stopnja Study programme and l

Strojniški vestnik (44) št. 3-4, str , 1998 Tiskano v Sloveniji. Vse pravice pridržane. UDK /.644:532:697.3:519.61/.64 Strokovni članek

Generatorji toplote

Strojniški vestnik (43) št. 9-10, str , 1997 Journal o f Mechanical Engineering (43) No. 9-10, pp , 1997 Tiskano v Sloveniji. Vse prav

POROČILO IZ KONSTRUKCIJSKE GRADBENE FIZIKE PROGRAM WUFI IZDELALI: Jaka Brezočnik, Luka Noč, David Božiček MENTOR: prof. dr. Zvonko Jagličič

VPRAŠANJA ZA USTNI IZPIT PRI PREDMETU OSNOVE ELEKTROTEHNIKE II PREDAVATELJ PROF. DR. DEJAN KRIŽAJ Vprašanja so v osnovi sestavljena iz naslovov poglav

Microsoft Word - ELEKTROTEHNIKA2_ junij 2013_pola1 in 2

Strokovni izobraževalni center Ljubljana, Srednja poklicna in strokovna šola Bežigrad PRIPRAVE NA PISNI DEL IZPITA IZ MATEMATIKE 2. letnik nižjega pok

Microsoft Word - CNC obdelava kazalo vsebine.doc

Strojni{ki vestnik 48(2002)5, Journal of Mechanical Engineering 48(2002)5, ISSN ISSN UDK : :519.61/.6

KLIMATSKE ZNAČILNOSTI LETA 1993 Aleška Bernot-lvančič* Leto 1993 je bilo glede na podatke 30-letnega klimatološkega niza nadpovprečno toplo, s

DOLŽNIK: MARJAN KOLAR - osebni steč aj Opr. št. St 3673/ 2014 OSNOVNI SEZNAM PREIZKUŠENIH TERJATEV prij ava terjatve zap. št. št. prij. matič na števi

HIDRAVLIČNI VENTILI Eksperimentalno preverjanje tokovnih sil v hidravličnih ventilih Blaž Bobnar, Anže Čelik, Franc Majdič Izvleček: Tokovna sila je e

Strojni{ki vestnik 47(2001)7, Journal of Mechanical Engineering 47(2001)7, ISSN ISSN UDK :006.06: UDC 69

PowerPoint Presentation

Strojni{ki vestnik 46(2000)7, Journal of Mechanical Engineering 46(2000)7, ISSN ISSN UDK :536.7 UDC :536

Javni in zasebni interes na področju storitev za starejše

Matematika Diferencialne enačbe prvega reda (1) Reši diferencialne enačbe z ločljivimi spremenljivkami: (a) y = 2xy, (b) y tg x = y, (c) y = 2x(1 + y

EVROPSKA KOMISIJA Bruselj, XXX [ ](2013) XXX draft DIREKTIVA KOMISIJE.../ /EU z dne XXX o spremembi prilog I, II in III k Direktivi 2000/25/ES Evropsk

1. Distributivni elementi.indd

MiT_1_2007.vp

Strojni{ki vestnik 46(2000)9, Journal of Mechanical Engineering 46(2000)9, ISSN ISSN UDK : UDC

Cenik 2019 Cenik velja od Termoizolacije IZOLIRAMO OD TEMELJEV DO STREHE

Strojniški vestnik (44) št. 3-4, str , 1998 Tiskano v Sloveniji. Vse pravice pridržane. UDK :536.48: Pregledni znanstveni članek

Microsoft Word - M

Microsoft Word - SI_vaja5.doc

Microsoft Word - M docx

Uradni list RS - 32/2004, Uredbeni del

PRESENT SIMPLE TENSE The sun gives us light. The sun does not give us light. Does It give us light? Raba: Za splošno znane resnice. I watch TV sometim

Analiza vpliva materiala, maziva in aktuatorja na dinamiko pnevmatičnega ventila

Športno društvo Jesenice, Ledarska 4, 4270 Jesenice, Tel.: (04) , Fax: (04) , Drsalni klub Jesenice in Zv

(Microsoft Word - 3. Pogre\232ki in negotovost-c.doc)

Strojni{ki vestnik 47(2001)3, Journal of Mechanical Engineering 47(2001)3, ISSN ISSN UDK :531.4/ UDC 62

Microsoft Word - ARRS-MS-FI-06-A-2010.doc

Predtest iz za 1. kontrolno nalogo- 2K Teme za kontrolno nalogo: Podobni trikotniki. Izreki v pravokotnem trikotniku. Kotne funkcije poljubnega kota.

PowerPointova predstavitev

Microsoft Word - ARRS-MS-CEA-03-A-2009.doc

UDK 535.2:535.34/.35:534-8 Enodimenzionalni model optičnega vzbujanja termoelastičnih valov 2.DEL: POMIKI MEJNIH PLOSKEV JANEZ MOŽINA - MARJAN DOVČ Na

FAKULTETA ZA STROJNIŠTVO Matematika 2 Pisni izpit 9. junij 2005 Ime in priimek: Vpisna št: Zaporedna številka izpita: Navodila Pazljivo preberite bese

IZVEDBENA UREDBA KOMISIJE (EU) 2018/ z dne 16. julija o spremembi Izvedbene uredbe (EU) 2017/ za razjasnitev in

Microsoft Word - Met_postaja_Jelendol1.doc

Predmet: Course title: UČNI NAČRT PREDMETA / COURSE SYLLABUS Numerična integracija in navadne diferencialne enačbe Numerical integration and ordinary

Transkripcija:

UDK 621.436:621.43.013:66.045 Termohidravlične razmere laminarnega toka tekočine y ozkih kanalih Thermo-Hydraulic Conditions of Laminar Fluid Flow in Narrow Channels MARJAN DELIČ - LEOPOLD ŠKERGET - IVAN ŽAGAR - FERDINAND TRENC V članku obravnavamo termohidravlične razmere laminarnega toka tekočine v ozkih kanalih z metodo končnih prostornin. V nerazvitih tokovnih razmerah dosega toplotna prestopnost visoke vrednosti tudi pri laminarnem toku tekočine. Posebno pozornost smo posvetili vplivu udara vtočnega curka. Analizirali smo vpliv debeline kanala na toplotno prestopnost. Numerično dobljene rezultate smo primerjali z izkustvenimi obrazci za hitrostno in temperaturno nerazvite profile. Vrednosti toplotne prestopnosti lahko uporabimo kot robne pogoje za računanje temperaturne porazdelitve v kombinirano oljno-zračno hlajenem valju motorja. The thermo-hydraulic situation of laminar fluid flow in narrow channels is studied by the control-volume approach. Due to the non-developed flow conditions, even in laminar fluid flow very high values of heat transfer coefficient are obtained. Special attention is given to the influence of the inflow jet. The influence of channel thickness on heat transfer coefficients is analysed. Numerically obtained results are compared with empirical expressions for velocity and temperature non-developed profiles. The results for heat transfer coefficients can be used as boundary conditions for temperature distribution computation in an oil-air cooling engine cylinder. 1 DEFINICIJA PROBLEMA Zaradi različnih temperaturnih obremenitev valja motorja, ki dosegajo svojo največjo vrednost v področju izpušnega kanala, dobimo po obodu neenakomerno temperaturno porazdelitev v steni valja. Temperaturno ovalnost lahko zmanjšamo z intenzivnim lokalnim hlajenjem, ki ga dosežemo z vstavitvijo oljnega kanala pravokotnega prečnega prereza v zgornji, temperaturno najbolj obremenjeni del zračno hlajenega motorja. Za pravilno izvedbo hlajenja je treba poznati lokalne hitrostne in toplotne razmere v kanalu. Razmere v kanalu je mogoče določiti numerično ali eksperimentalno. Problem smo reševali numerično, ker je numerična rešitev cenovno ugodnejša in preprosteje izvedljiva. Pri numeričnem reševanju je tudi preprosteje spreminjati robne pogoje in izpeljati geometrijske spremembe. Geometrijska oblika kanala in robni pogoji, ki smo jih povzeli po literaturi 191, so prikazani na sliki 1. Pri vtoku smo podali masni pretok, ustrezen prostorninskemu pretoku 5 1/min, pri iztoku smo prepisali referenčni tlak, po stenah kanala pa je hitrost enaka nič. Na ceveh smo podali adiabatne robne pogoje, na vseh drugih trdnih površinah pa smo predpisali konstantno temperaturo stene. V prvih izračunih smo podali temperaturo stene T = 110 C, v nadaljnjih pa smo na notranji steni podali temperaturo T = 165 C in na zunanji T =115 0C, kar je bližje realnim razmeram v valju. 1 PROBLEM DEFINITION Due to different thermal loads of the engine cylinder with peak value in the vicinity of the exhaust channel, there is pronounced asymmetric circumferential temperature distribution in the cylinder wall. This temperature ovalty can be minimized by controlled intensity of the local cooling, which can be obtained by introducing a curved square cross-section oil channel in the upper, thermally most loaded part of an air cooled engine cylinder. For correct realisation of cooling it is necessary to know the local thermo-hydraulic conditions in the channel. Conditions in the channel can be defined numerically or experimentally. The problem was solved numerically, because the numerical solution is economicaly more favourable. With the numerical solution it is also easier to change boundary conditions and introduce geometrical changes. The geometry of the channel and boundary conditions, summarized from reference 191, is shown in Figure 1. On the inflow, the mass flow which is equal to a volume flow of 5 1/min is given, on the outflow, the reference pressure is prescribed, and on the walls the velocity vanishes. On the pipes, adiabatic boundary conditions are given, and on all other solid walls the constant temperature of the wall is prescribed. In the first calculations the constant surface temperature of T = 110 C is given, and in the next calculations the temperature of the inner wall was T = 165 C, and on the outer one T = 115 C, which is closer to the real conditions in the cylinder.

1 Sl. 1. Geometrijska oblika oljnega kanala in robni pogoji Fig. 1. Geometry and boundary conditions of oil channel Temperatura vtočnega olja je 100 C. Prav tako smo analizirali tudi vpliv temperaturne odvisnosti snovskih lastnosti, zato se izračuni razlikujejo tudi po upoštevanju ali neupoštevanju temperaturne odvisnosti snovskih lastnosti. Pri izračunih, pri katerih nismo upoštevali temperaturne odvisnosti snovskih lastnosti, smo te vzeli pri T = 100 C za prvi in pri T = 140 C za drugi primer. Za reševanje problema je uporabljen programski paket TASCflovv 2.3. Konvergenco rezultatov smo proučili na več mrežah, od katerih je najgostejša imela 261460 vozlišč. Pomemben vpliv na toplotne razmere v kanalu ima debelina kanala, ker se s tem bistveno spremenijo tokovne razmere v kanalu. Zato smo dodatno analizirali vpliv debeline kanalčka na toplotno prestopnost. V ta namen smo sestavili mrežo oblike kvadra dimenzij debelina x 37 x 300. Mreža je imela 115661 vozlišč (31 x 91 x 41), debelino kanala pa smo nastavili na 0,5, 1, 2 in 4 nun. Pri vtoku v kanal smo podali masni pretok in vtočno temperaturo fluida T = 100 C, pri iztoku točkovni referenčni tlak in na stenah kanala temperaturne robne pogoje Ts = 110 C. Masni pretok smo linearno povečevali s površino prečnega prereza kanala, tako da je bila srednja hitrost fluida v kanalu vedno enaka 1 m /s. Pri izračunu smo upoštevali temperaturno odvisnost snovskih lastnosti. The temperature of the inflow fluid is given at 100 C. Influences of the temperature dependence of the material properties were also analysed, therefore the calculations are also distinguished by consideration or non-consideration of the temperature dependence of the material properties. In the calculations where influence of the temperature dependence of the material properties is not considered, they are given at T = 100 C for the first, and T = 140 C for the second case. To solve the problem, a TASCflow 2.3. computer code was used. Because of the convergence, more meshes were generated, the finest of which has 261460 nodes. Modification of the channel thickness represents a significant influence on the functionality of it because of which the conditions in the channel essentially change. Therefore, the influence of the channel thickness on the heat transfer coefficient was additionally analysed. For this purpose a mesh with dimension thickness x 37 x 300 was created. The mesh has 115661 nodes (31 x 91 x 41), and the thickness of the channel at 0.5, 1, 2 and 4 mm is given. At the inflow, the mass flow and inflow fluid temperature T = 100 C are given. At the outflow reference pressure is given, and on the walls of the channel constant temperature boundary conditions Ts = 110 C are given. The mass flow was linearly increased. with a cross section area of the channel, so that the fluid mean speed in the channel is equal to 1 m /s. In the calculations the influence of the temperature dependence on the material properties was considered.

Snovske lastnosti fluida (motorno olje SAE The material properties of the fluid (motor 15 W/40) smo podali z naslednjimi izrazi, pov- oil SAE 15W/40) are given by the following žetimi iz literature till, npr. dinamična viskoz- expressions [111, e.g. the dynamic viscosity: nost: n m = (172,37 e -,0242(T-288,i5) + 13) jo 3 [pa s ] specifična toplota: specific heat: cp(tì = 622,72 + 4,187 T - 273,15 kg K toplotna prevodnost: thermal conductivity: W A( T) = 0,16094-0,000057143T mk in gostota: and density: kg p( Ti =890,1 (d - 0,00065 ( T - 293,15)) m kjer je temperatura T podana v K. where temperature T is given in K. 2 REZULTATI Numerično dobljene vrednosti toplotne prestopnosti smo primerjali z vrednostmi, dobljenimi iz izkustvenih kriterijskih enačb za Nusseltovo število (Nu), in sicer z izrazom, povzetim iz literature [61 za povprečno Nu število od vstopa do dolžine x: 2 RESULTS The numerical results obtained for heat transfer with empirical expressions for Nusselt number (Nu) L61 were compared. For average Nu number, the expression: Nu = 6,998 + 0,0668 Re Pr 1 + 0,04 - f - \ R ß Pr ( 1 ) oziroma z izrazom, povzetim iz literature L91 za was used, and for local Nu number [91: lokalno Nu število: Nux = 1,077 Re Pr X L- dh (2). V izraz (1) smo uvedli korigirano konstanto, ki upošteva razmerje stranic prečnega prereza kanala (37 : 1). V obeh obrazcih je upoštevan hidravlični premer (dh =4 A /O), kjer sta A in O površina in obseg prečnega prereza kanala. Re {Re = v dh p/rj) in Pr (Pr = cp r}/ X) sta Reynoldsovo in Prandtlovo število. Vpliv ukrivljenosti kanala smo zajeli z odvisnostmi L81: The constant in equation (1) is changed to consider the relation between the edges of the channel cross-section (37:1). In both expressions the hydraulic diameter {dy1=4 A / O) is considered, where A and O are area and circumference of the channel cross-section. Re {Re = v dh p/rj) and Pr {Pr -c p r}/a) are Reynolds and Prandtl numbers. Influence of the channel curvature was considered by relations [81: Nur =Nu sr, ^ U X R ^ U X er (3),

kjer je er korekcijski faktor relativne ukrivlje- where er is the correction factor for the relative nosti kanala, ki ga računamo po 111: curvature, which was solved from 111: er = 1 + 1,77 pri čemer je R polmer krivine kanala. Numerične rezultate smo obdelali z izrazoma: d h R (4), where R is the radius of the curvature. Numerical results were treated with expressions: in and Nux = <xx d h A (5), kjer je: where : oc = j- J ocx dx (6), in and ocx = dx A (7). Temperaturna razlika je podana z izrazom: Temperature difference is given by the equation: AT *»1 m = 1 T c - *n T (8), kjer je Ts temperatura stene in Tm srednja temperatura po prečnem prerezu. Srednjo vtočno (rmv) in iztočno (Tmi) temperaturo iz kanala izračunamo z izrazom: where Ts is the wall temperature and Tm is the mean temperature at the cross section. The mean inflow (rmv) and outflow (Tmi) temperature from the channel was determined by: Tm = J Ac p v CpTdA m cr (9). 2.1 Ukrivljen kanal Na sliki 2 je prikazan potek tokovnic skozi ukrivljen kanal. Pri dani geometrijski obliki in pretoku olja (5 1/min) teče skozi krajšo vejo kanala 66,7 % in skozi daljšo vejo 33,3 % masnega pretoka fluida. Na sliki je jasno vidno intenzivno mešanje tekočine pri vstopu v kanal in vračanje dela toka v daljšo vejo zaradi zvečanja hidravličnih uporov v krajši veji kanala. Na sliki 3 je iz vzdolžnega prereza jasno razviden vpliv vtočnega curka in zožitve kanala. Zaradi udarca curka prihaja do cirkulacije fluida v vzdolžni in prečni smeri, kar dodatno poveča toplotne tokove skozi stene kanala. Na slikah 4 in 5 je prikazan potek povprečne prečne toplotne prestopnosti vzdolž obeh vej kanala. Vidimo, da se numerično dobljene vrednosti dobro ujemajo z vrednostmi, dobljenimi iz obrazcev 1 in 2, ki smo jih izbrali za primerjavo z numeričnimi rezultati. Največje vrednosti dobimo na vtoku v veje, nato pa prestopnost počasi pada 2.1 Curved channel Figure 2 presents streamlines in the curved channel. At given geometry and oil flow (5 1/min) through the shorter branch the mass flow of the oil is 66.7 %, and through the longer one 33.3 %. On the figure there is clearly evident intensive fluid mixing at the inflow of the channel and the returning part of flow in the longer branch because of growing hydraulic dissipation in the shorter branch of the channel. On Figure 3, the influence of impinging jet and channel contraction from longitudinal section is clearly evident. Because of the impinging jet fluid, circulation is impeded in longitudinal and cross-section, which additionally increases heat flux through the wall of the channel. In Figures 4 and 5, the average cross heat transfer through both branches of the channel is shown. It is evident that the numerical results are in good agreement with the results obtained from equations (1) and (2), which were selected for comparison with numerical results. The greatest values are on the inflows in the branches,

Sl. 2. Tokovnice Fig. 2. Streamlines Sl. 3. Hitrostna porazdelitev v vstopnem območju ( 1/4, 2/4, 3/4 višine kanala) Fig. 3. Velocity distribution in inlet region (1/4, 2/4, 3/4 height of the channel) do samega izstopa, kjer se, zaradi razširitve kanala (gl. sl. 1) in s tem stanjšanja mejne plasti, spet sunkovito poveča. Vzdolž krajše veje kanala dosega toplotna prestopnost višje vrednosti zaradi večjega masnega pretoka in manjše dolžine kanala (razvoj mejne plasti), s čimer dosežemo and then the heat transfer decreases due to outflow, where - because of extension of the channel (see Fig. 1) and with the thinning of the boundary layer - heat transfer instantly increases. Through the shorter branch of the channel, heat transfer has higher values because of the greater mass flow and the shorter branch of the channel (boundary layer development), and with

intenzivnejše hlajenje na toplotno bolj obremenjenem delu valja motorja. Na zožitvah in razširitvah kanala se hitrostna mejna plast močno stanjša, kar povzroči naglo povečanje toplotnih tokov. Za prekinitev krivulje povprečne toplotne prestopnosti (daljša veja kanala) na njenem osrednjem delu je kriv predpis periodičnih robnih pogojev. that the cooling is more intensive on the thermically more loaded part of the engine cylinder. On contractions and extensions of the channel, the velocity boundary layer becomes thinner, which is the reason for the strong increase of heat fluxes. The curve break of mean heat transfer (longer branch of the channel) on the middle part is a consequence of the prescribed periodical boundary conditions. n u m erič n i re zu lta ti enačba (1 ) + vpliv u krivljen osti (3 ) n u m erič n i re zu lta ti enačba (2 ) + vpliv u k rivljen o sti (3 ) n u m eric a l resu lts equation (1 ) + in flu en ce o f cu rvatu re (3 ).n u m erical results equation (2 ) + influence o f cu rvatu re (3 ) 220.0 171.6 155.-6 139.3 KOT-STOPINJE ANGLE -DEGREES SI. 4. ax in a vzdolž krajše veje kanala Fig. 4. ocx and <x along the shorter branch of the channel n u m erič n i re zu lta ti enačba ( I f + vp liv u k riv lje n o sti (3 ) n u m e rič n i rezu lta ti enačba (2 ) + vpliv u k rivljen o sti (3 ) n u m eric a l resu lts equation (1 ) + in flu en ce o f cu rva tu re (3 ) n u m eric a l resu lts equation (2 ) + influence o f cu rvatu re (3 ) 2 3 7.0 2 64.2 2 9 1.4 3 18.6 3 45.8 3 73.0 4 0 0.2 4 27.4 KOT-STOPINJE ANGLE-DEGREES SI. 5. ax in 5T vzdolž daljše veje kanala Fig. 5. oc. x and ččalong the longer branch of the channel

Slika 6 prikazuje primerjavo povprečnih toplotnih tokov po obodu za notranjo in zunanjo steno kanala za primer temperaturno odvisnih snovskih lastnosti. V okolici vtoka in iztoka je kanal razširjen (manjše povprečne hitrosti po prečnih prerezih), zaradi česar so lokalni maksimumi toplotnega toka na zožitvah in razširitvah kanala. K> Figure 6 presents a comparison of average heat fluxes at circumference for inner and outer channel wall, for example where the temperature dependence of material properties is considered. In the vicinity of inflow and outflow the channel is extended (lower mean velocity at cross-section), therefore local maxima of heat flux occur on contractions and extensions of the channel. ANGLE DEGREES SI. 6. Povprečni toplotni tokovi vzdolž kanala za notranjo in zunanjo steno Fig. 6. Average heat flux along the channel for inner and outer wall Na grafu lahko zaznamo vpliv vtočnega curka po izbočenosti krivulje na mestu vtoka. V prvem primeru (Ts = 110 C), kjer so temperaturne razlike majhne, ne naredimo večje napake, če ne upoštevamo temperaturne odvisnosti snovskih lastnosti, kajti ob majhnih temperaturnih razlikah se te zelo malo spremenijo. V primerih, kjer imamo opraviti z večjimi temperaturnimi razlikami (kakršni so tudi realni robni pogoji valj motorja z notranjim zgorevanjem), pa z zanemaritvijo temperaturne odvisnosti snovskih lastnosti naredimo že večjo napako. 2.2 Raven kanal S slike 7 je razvidno, da je toplotna prestopnost precej večja pri ožjih kanalih. Slika 8 prikazuje segrevanje fluida v kanalih različnih debelin. On the graph one may clearly see the influence of the inflow jet from the curve convexity on the inflow region. In the examples where temperature differences are small, errors are not large, if the temperature dependence of material properties is not considered, because w ith small temperature differences they are nearly constant. In the examples where the temperature differences are larger (as at the real boundary conditions - cylinder of internal combustion engine) a greater error occurs due to neglect of material properties temperature dependence. 2.2 Straight channel From Figure 7 it is evident that heat transfer is greater at the thinner channel. Figure 8 presents fluid heating in the different thick channels.

* debelina kanala 0.5 m m + debelina kanala 1 m m X debelina k anala 2 m m K debelina kanala j m m th ick n ess 0.5 m m th ick n ess 1 m m th ick n ess 2 m m th ick n ess L m m.0000.0^00. 0800.1200.1600 X n.2h00 Sl. 7. Primerjava povprečnih toplotnih prestopnosti za različne debeline kanala Fig. 7. Comparison of average heat transfer coefficients for different channel thicknesses * debelina kanala 0.5 m m + debelina kanala 1 m m.0000.0h00 Sl. 8. Srednja temperatura olja po prečnih prerezih za različne debeline kanala Fig. 8. Mean oil temperature at cross-sections for different channel thicknesses V ožjih kanalih je prenos toplote intenzivnejši, kljub manjšemu masnemu pretoku tekočine. Večja toplotna prestopnost v ožjih kanalih je posledica strmejših prisilno oblikovanih profilov, ki so odvisni od debeline kanala (manjša stranica prečnega prereza). S tem povezani so tudi veliko večji tlačni padci v ožjih kanalih, ki so za računane primere v razmerjih 1,00 : 3,69 : 14,16 : 54,32 glede na najdebelejši kanal. In the thinner channels the heat flux is bigger in spite of the lower mass flow of the fluid. Higher heat transfer in the thinner channel is the consequence of larger velocity gradients, which are conditioned by channel thickness (lower edge of cross section). The pressure drop is larger in thinner channels, which are for the calculated examples in proportions 1.00 : 3.69 : 14.16 : 54.32 in relation to the thickest channel.

3 SKLEP Z dodatnim oljnim hlajenjem zmanjšamo temperaturne obremenitve in njihovo obodno neenakomernost na valju dieselskega motorja. Dobljeni numerični rezultati se dobro ujemajo z izkustvenimi obrazci. V nadaljnjih izračunih pri realnih robnih pogojih (valj motorja) bo treba upoštevati temperaturno odvisnost snovskih lastnosti, predvsem zaradi temperaturne odvisnosti viskoznosti olja. V vstopnem in izstopnem območju pride do mešanja fluida zaradi vpliva vstopnega curka in tlačnih razlik v kanalu, kar ob razvijanju hitrostne in toplotne mejne plasti še dodatno poveča intenzivnost prenosa toplote. Največje vrednosti toplotnih tokov se pojavijo pri zožitvi kanala (vstop) zaradi zmanjšanja pretočnih prerezov. Vrednosti toplotne prestopnosti bomo uporabili kot robne pogoje pri računanju temperaturne porazdelitve v kombinirano oljno-zračno hlajenem valju motorja. 3 CONCLUSION With additional oil cooling, temperature loads and their circumferential ovalty on Diesel engine cylinder are reduced. The numerical results are in good agreement with the empirical expressions. Computations with real boundary conditions (engine cylinder) are required in order to consider the temperature dependence of material properties, mostly because of the temperature dependence of oil viscosity. In the inlet and outlet region, fluid is mixed due to the influence of inflow jet and of pressure drops in the branches, which at developing velocity and thermal boundary layer increases the intensity of heat transfer. Maximum values of heat fluxes occur at the contraction of the channel (inlet). The results for heat transfer will be used as boundary conditions for a combined oil-air cooling engine cylinder. ZAHVALA Delo je bilo opravljeno v sklopu projekta Numerično in eksperimentalno modeliranje prenosa toplote v valju motorja s kombiniranim hlajenjem, ki ga financira Ministrstvo za znanost in tehnologijo. ACKNOWLEDGEMENT The research has been financially supported by the Ministry of Science and Technology of the Republic of Slovenia under the project title Numerical and Experimental Solution of Heat Transfer in the Combined Air-oil Cooling Engine Cylinder. 4 LITERATURA 4 REFERENCES 111 Alujevič, A.-Škerget, P.: Prenos toplote. Tehniška fakulteta Maribor, 1990. 121 TASCflow User Documentation - Version 2.2, January 1993. 131 Bukovec, J.: Tokovno-toplotne razmere v kratkih ukrivljenih kanalih, Diplomsko delo, Maribor, 1994. 141 Delič, M. Škerget, P. Žagar, L: Numerical and Experimental Validation of Thermo-Hydraulic Conditions in the Narrow Channels. Advanced Computational Methods in Heat Transfer III, Southampton, 1994. 151 Delič, M.-Škerget, P.-Žagar, I.-Bukovec, J,- Trenc, F.: Numerična analiza termo-hidravličnih pogojev v ozkih ukrivljenih kanalih. Kuhljevi dnevi, Šmarješke toplice, 1994. 161 Incropera, F.P.- De Witt, D.P.: Introduction to Heat Transfer. John Wiley, 1990. 171 Rohsenow, W.M.-Hartnett, J.P.-Ganić, E.N.: Handbook of Heat Transfer Fundamentals. McGraw-Hill, 1985.

181 Sukhatme, S.P.: Corelations in Single-Phase Convection Heat Transfer. Heat Transfer Equipment Design. Hemisphere Publishing Corporation, 1988. 191 TAM - Razvojno tehnični inštitut: Razvoj sodobnega in ekološko ustreznega dizelskega motorja. Fazno poročilo na projektu, Maribor, 1992. 1101 Trene, F.: Analiza temperaturnega stanja na valju zračno hlajenega motorja. Doktorska disertacija, Ljubljana, 1991. 1111 Vičič, R.: Študij toplotnih tokov na modelu oljnega kanala v segmentu valja zračno hlajenega motorja, Magistrsko delo, Ljubljana 1992. Naslova avtorjev: Marjan Delič, dipl. inž., prof. dr. Leopold Škerget, dipl. inž., doc. dr. Ivan Žagar, dipl. inž. Fakulteta za strojništvo Univerze v Mariboru Smetanova 17 62000 Maribor, Slovenija doc. dr. Ferdinand Trene, dipl. inž. Fakulteta za strojništvo Univerze v Ljubljani Aškerčeva 6 61000 Ljubljana, Slovenija Authors Addresses: Marjan Delič, Dipl. Ing., Prof. Dr. Leopold Škerget, Dipl. Ing., Doc. Dr. Ivan Žagar, Dipl. Ing. Faculty of Mechanical Engineering University of Maribor Smetanova 17 62000 Maribor, Slovenia Doc. Dr. Ferdinand Trene, Dipl. Ing. Faculty of Mechanical Engineering University of Maribor Aškerčeva 6 61000 Ljubljana, Slovenia Prejeto: Received: 15.6.1995 Sprejeto: Accepted: 31.8.1995